29.08.2019
Cabel length is halved since the supply and GND line form the entire length.
L
Cable
=
L
wire
/ 2
Legend:
U = Voltage drop ( 5 V supply
– minimum encode supply)
R = Wire resistance
I = Maximum required encoder current
ρ (rho) = Specific resistance of the wire (0.017 Ω for copper)
L
wire
= Entire wire length (supply line + ground line)
L
cable
= Entire cable length (
L
wire
/ 2)
A = Encoder cable cross section