![SIGMATEK MDD 111-1 Manual Download Page 16](http://html1.mh-extra.com/html/sigmatek/mdd-111-1/mdd-111-1_manual_1268140016.webp)
MDP 102-1
Page 16
29.08.2019
Hardware
•
Mains input is fed to the power rectifier, the input filter and the inrush
circuit
•
DC-link connection for connecting the DC-link to other drives for power
distribution
•
Regen unit with internal regen resistor.
•
Auxiliary power supply input for the internal supply
•
Separate power supply input for the holding brake for safety reasons
•
Integrated safety functions
•
Micro controller system with communication unit
•
IGBT
– power stage with isolated current measurement (short circuit
protected)
•
Feedback converter for resolver and high resolution feedback devices
•
8 digital Capture-inputs to record the momentary actual position of the
selected axis.