Instructions, use and maintenance manual
Pag. 35/48
TAURO 35-35PLUS-40-40PLUS
14.5. Special maintenance
For operations that are not specifically mentioned in the manual, you must refer to personnel
authorised by the seller. To replace the motor and electronic boards or following a machine fall,
contact our customer service (for on-site assistance or an in-factory inspection).
Faults - replacement of the mobile guard micro-switch: remove the screws holding the upper
casing together with the structure, place the upper casing onto a flat surface and make sure that the
sheath containing the wires is not taut.
Check the micro-switch, change it in case of failure and/or breakage. Loosen/tighten the screws (1)
when disassembling/assembling the head micro-switch.
Should the power cable be damaged, replace it with a H07RN/F cable with a 3x1.5 mm cross-section
2
.
Electrical interventions: they must be carried out by a qualified electrician, referring to the diagrams
attached at the end of the manual.
Please note that both the cam screws and the micro-switch screws are blocked with
Bblock230, which is a product suitable for clamping screws and/or nuts that come
loose due to vibrations (Bblock230 is a highly resistant product and can only be
removed by heating the product at about 250°C (with naked flame or furnace);
obviously, check that the product does not contain material flammable at this
temperature). Before using Bblock230, make sure that the micro-switch is correctly
positioned on the head and fasten the screws (1), put the upper casing and the head
front casing back and tighten the screws. Turn on the machine, if it works properly it
should stop in FOUR seconds from lifting the mobile guard. Ensured that the
machine works properly, release the master switch, remove the upper casing and the
head front casing, loosen the micro-switch nut, put the thread locker and tighten the
nut, then do the same for the other screw. Put the casings back and tighten the
screws