background image

2

• In standby, the siren has seven different selectable, operating modes of the five LEDs of the  
 FLASH.
• Five different alarm sounds (selectable) and separate sound for fire alarm.
• It has two independent activation inputs, which operate with a positive or negative voltage 
  interruption and an independent activation input for fire detection.
• The siren will follow the alarm duration of the control panel. However, in case of interruption  
  of or short circuit of the cables that connect the siren with the Alarm Panel an alarm will be 
 triggered.
• Specifically:
-  Sounds an alarm with duration five (5) minutes, if the power supply cables are cut-off (+12 V) 
-  Sounds an alarm with duration fifteen (15) minutes, if the TRIGGER cable is cut-off
-  Sounds an alarm with duration five (5) minutes, if the power supply cables and TRIGGER cable  
  are cut-off simultaneously 
• The siren, can be programmed so, when it starts operating will sound at low volume for 
  5 seconds and then the intensity will turn to normal level. 
• The siren will sound an alarm of up to five (5) times in 24 hours (selectable). This time counts  
  from the first activation of the siren and the process is canceled just spend the 24 hours or if  
  there is siren power cut off for two seconds.
• The siren’s battery voltage is verified every hour, and when it drops below 11.5V (Low Battery),  
  the “FLT OUT” output (FAULT OUT) is activated. The “FLT OUT” output is also activated when  
  the battery is disconnected from the siren or when its voltage drops below 10 V (Battery Fail).
•  When the battery voltage exceeds 13.8 V, charging is stopped to protect the battery from  
 overcharging.
• It has short circuit protection on the battery charging (of the cables) output. Also, it has 
  overcurrent and short circuit protection for the battery with simultaneous activation of the “FLT  
  OUT” output.
•  It has protection against reverse connection of the battery poles with simultaneous LED 
 indication. 
•  When the siren is in standby mode and its battery voltage drops below 10.0 V, siren’s flash  
  stops flashing.
• Built in TAMRER switch to protect the siren from the opening the outer casing and the 
  detachment from the wall. The Tamper is provided with free contacts for connection to the  
  Alarm panel.
• The FSD has a built-in 3-axis accelerometer with adjustable detection sensitivity, which, in any  
  attempt to vandalize or change siren slope more than 45o, triggers an alarm to the siren and  
  simultaneously triggers the output “ALR OUT” ALARM OUTPUT).
• The FSD version has a built-in foam detector, which, in any attempt to sabotage the siren with  

General Characteristics 

Description

Self-powered and self-protected electronic siren with built-in FLASH 270°, in two shades (red
and blue), for easy detection of the area from which the alarm comes. It is an ideal combination
of stylish design and quality construction and is manufactured under the most, strict safety
standards. The outer cover is made of high-strength polycarbonate, suitable for outdoor use.
Inside it is protected by a metal cap made of galvanized sheet metal (in the Basic version) and it
has protection against opening the outer lid or detaching the siren from the wall. In addition, in
the IRIS PLUS / FSD version, there is a vibration detector to protect the siren from knocks and a
dual infrared foam detection sensor for protection against sabotage through foaming.

Summary of Contents for IRIS PLUS

Page 1: ...1 INSTALLATION MANUAL IRIS PLUS Outdoor self powered siren...

Page 2: ...o protect the battery from overcharging It has short circuit protection on the battery charging of the cables output Also it has overcurrent and short circuit protection for the battery with simultane...

Page 3: ...and foam detector and then you can open the cover of the siren to change the battery or make service without the siren sound The built in FLASH has five high brightness and low power LEDs which are sh...

Page 4: ...tage on this input drops bellow 5 8 V DC Activation from Trigger It is balanced when there are 0VDC on the Trigger input It sounds an alarm if the voltage of power supply is interrupted or if the volt...

Page 5: ...ACTIVATION INPUT 12V FOR FIRE ALARM SIGN INPUT 12V FOR AUDIBLE AND VISUAL VERIFICATION OF THE CONTROL PANEL STATUS TC INPUT 12V FOR TAMPER 3 AXIS ACCELEROMETER AND FOAM DETECTOR CANCELATION FLT OUT LO...

Page 6: ...nect the siren to the panel as explained in the connection terminals on page 5 and the following wiring diagram 6 When you finish cable connections connect the battery to the siren The siren can remai...

Page 7: ...emain open for only 10 seconds and then be deactivated If a fault is detected on the battery the FLT OUT output will remain activated after the end of 10 seconds and until the fault is restored Once t...

Page 8: ...here is a voltage at the siren power input 12V or every five minutes when there is no voltage If during the test the battery voltage is lower than 11 5V we have a low battery voltage indication and if...

Page 9: ...siren will follow If all the LEDs are off then the siren will have no lighting at standby mode To store this setting into memory press the MENU button The LED with the indication L S will turn on Sele...

Page 10: ...twenty four hours the duration of each alarm should be longer than 20 seconds Each time you press SELECT button you will hear the sound of the siren and will turn on or turn off all five LEDs of the...

Page 11: ...urns to standby mode after three minutes without pressing any of the two buttons This function allows you to open the siren for maintenance or to change the battery without the siren being activated b...

Page 12: ...e battery voltage is lower than this replace the battery and connect the new battery keeping in mind to use the correct polarity 4 Check for signs of water or insects entering the siren and clean if n...

Reviews: