Factory Programming

Resetting the factory settings is done when the siren is in a standby mode. To restore the factory 

settings, simultaneously press the MENU and SELECT buttons for three seconds until you hear the 

confirmation signal (five BEEP). Then the LEDs with 

“SOUND”

 and 

“5-24” 

indication will flash for 

one second and the siren will return to Standby mode.

Selecting the Foam detector function (Only in IRIS PLUS FSD)

Exit Setup

As soon the LEDs 

“FLASH” & “L/S” & “Hi-Lo”

, light, press “SELECT” button to select if the foam

detector will be active or inactive. Every time you press “SELECT” button, will increase or decrease

the brightness of the three LEDs. When the LEDs have a low brightness, the foam detector will be 

deactivated and when the light level is high the foam detector will be activated.

 

Press “MENU” button to save your setting and navigate to next selection. The LED 

“SOUND”

,  

  will light to indicate you are in the first step of setup.

 

To store this setting into memory, and navigate to the next menu, press the MENU button. 

    The LEDs with the indication  

“FLASH” & “L/S

  & 

“Hi-Lo”

, will turn on.

To exit setup press continuously “MENU” button until you hear the confirmation sound (5 BEEPs). 

Immediately, the LEDs 

“SOUND” & “5-24”

 will turn on for 1 second and the siren will enter 

standby mode.

  

Note

   

Also, the siren exits programming and returns to standby mode, after three minutes  

   

without pressing any of the two buttons.

This function allows you to open the siren for maintenance or to change the battery without the 

siren being activated by the tamper. A prerequisite is that the “TC” input of the siren has been  

connected to the panel, as described in the chapter on Selecting the siren’s Operation Mode, in 

the section “Bypassing the Siren’s Tamper - Removing the Lid”.

Whenever you wish to open the siren when it is installed and connected to the Alarm panel, follow 

the procedure below:

 

As soon as you have connected the siren’s TC to the corresponding output of the panel, 

  activate the corresponding PGM of the panel or, in the case of a Sigma panel, arm and 

  immediately disarm the panel to apply + 12V to the TC input. When you do the above, you have  

  ten minutes to open the siren lid without activating an alarm, because Tamper is inactive for  

  that period. After opening the lid, the time that the siren may remain open becomes unlimited  

  and is reset when the siren lid is closed again.

 

Upon completing service, close the lid and secure it with the corresponding screws. As soon as  

  you close the lid, the two siren LEDs will light for five seconds, and when a minute has elapsed  

  since you close it, the siren will return to normal operation and Tamper will be active again.  

  Also, for security reasons, siren’s Tamper is always active, as soon as 10 minutes have elapsed  

  since the voltage is applied to the TC, without opening the lid.

Opening the siren (Engineer Mode)

Summary of Contents for IRIS PLUS

Page 1: ...1 INSTALLATION MANUAL IRIS PLUS Outdoor self powered siren...

Page 2: ...o protect the battery from overcharging It has short circuit protection on the battery charging of the cables output Also it has overcurrent and short circuit protection for the battery with simultane...

Page 3: ...and foam detector and then you can open the cover of the siren to change the battery or make service without the siren sound The built in FLASH has five high brightness and low power LEDs which are sh...

Page 4: ...tage on this input drops bellow 5 8 V DC Activation from Trigger It is balanced when there are 0VDC on the Trigger input It sounds an alarm if the voltage of power supply is interrupted or if the volt...

Page 5: ...ACTIVATION INPUT 12V FOR FIRE ALARM SIGN INPUT 12V FOR AUDIBLE AND VISUAL VERIFICATION OF THE CONTROL PANEL STATUS TC INPUT 12V FOR TAMPER 3 AXIS ACCELEROMETER AND FOAM DETECTOR CANCELATION FLT OUT LO...

Page 6: ...nect the siren to the panel as explained in the connection terminals on page 5 and the following wiring diagram 6 When you finish cable connections connect the battery to the siren The siren can remai...

Page 7: ...emain open for only 10 seconds and then be deactivated If a fault is detected on the battery the FLT OUT output will remain activated after the end of 10 seconds and until the fault is restored Once t...

Page 8: ...here is a voltage at the siren power input 12V or every five minutes when there is no voltage If during the test the battery voltage is lower than 11 5V we have a low battery voltage indication and if...

Page 9: ...siren will follow If all the LEDs are off then the siren will have no lighting at standby mode To store this setting into memory press the MENU button The LED with the indication L S will turn on Sele...

Page 10: ...twenty four hours the duration of each alarm should be longer than 20 seconds Each time you press SELECT button you will hear the sound of the siren and will turn on or turn off all five LEDs of the...

Page 11: ...urns to standby mode after three minutes without pressing any of the two buttons This function allows you to open the siren for maintenance or to change the battery without the siren being activated b...

Page 12: ...e battery voltage is lower than this replace the battery and connect the new battery keeping in mind to use the correct polarity 4 Check for signs of water or insects entering the siren and clean if n...

Reviews: