Select the siren’s activation from Tamper

As soon as the LEDs 

“SOUND” & “5/24”

 light press “SELECT” button to select if the siren’s 

Tamper, will activate the 

“Tamper”

 output, but it will activate the siren, also.  When the brightness 

of these LEDs is low, 

“Tamper”

 does not activate the siren but only the 

“Tamper”

 output while 

when the brightness of the LEDs is high, Tamper simultaneously activates the Tamper output and 

the siren (factory programming).

 

Press “MENU” button to save your setting and navigate to next selection. The LEDs with the 

   indications ενδείξεις 

“FLASH”

 & 

“Hi-Lo”

.

Select the level of the siren sound at the start of alarm (pre-alarm)

Once the LED 

“Hi-Lo”

 lights, press the SELECT button to select the level of the siren sound at the

start of the alarm. Each time you press SELECT button, the siren will sound with high or low sound

level (Hi-Lo). If you select low sound level, the siren will sound at low volume level for 8 seconds at

the beginning of its operation and then gives all its intensity. If you select high sound level, the 

siren will sound with all its intensity in case of alarm. (factory programming)

 

Press “MENU” button to save your setting and navigate to next selection. The LED with the 

 indication 

“5-24”

 will light.

Select the number of siren’s activations during twenty-four hours 

(maximum daily alarms)

As soon as the LED 

“5-24”

 lights, press “SELECT” button to select if the siren will sound every 

time the alarm system is activated or only five times during a twenty-four hours (the duration of 

each alarm should be longer than 20 seconds). Each time you press “SELECT” button, you will 

hear the sound of the siren and will turn on or turn off all five LEDs of the siren. If you choose the 

situation has light up all five LEDs, then the siren will alarm up to five times during the day. If you 

chose the situation with five LEDs turned off, then the siren will operate always, repeatedly if an 

alarm is given (factory programming).

 

Press “MENU” button to save your setting and navigate to next selection. The LEDs 

“SOUND”

  

 & 

“5/24”

, will light simultaneously.

Adjusting siren sensitivity to blows 

(Only in IRIS PLUS FSD)

Adjusting siren sensitivity to drilling 

(Only in IRIS PLUS FSD)

When the LEDs with the indication “FLASH” & “Hi-Lo” will turn on, use the button SELECT to adjust 

the siren’s sensitivity to blows  which are detected by the 3-Axis accelerometer . Each time you press 

“SELECT” button, you will turn on or turn off one or more of the five LEDs, which show the sensitivity 

of the siren in blows.  

When all five LEDs are turned off, this function is deactivated it remains, 

however, active detection of inflection.

 

To store this setting into memory, and navigate to the next menu, press the MENU button. 

    The LEDs with the indication  

“FLASH”

  & 

“Hi-Lo”

, will turn on

When the LEDs with the indication “FLASH” & “Hi-Lo” turn on, use the button SELECT to adjust the 

siren’s sensitivity to drilling  which are detected by the 3-Axis accelerometer. Each time you press 

“SELECT” button, you will turn on or turn off one or more of the five LEDs, which show the sensitivity 

of the siren to drillining.  

When all five LEDs are turned off, this function is deactivated.

Summary of Contents for IRIS PLUS

Page 1: ...1 INSTALLATION MANUAL IRIS PLUS Outdoor self powered siren...

Page 2: ...o protect the battery from overcharging It has short circuit protection on the battery charging of the cables output Also it has overcurrent and short circuit protection for the battery with simultane...

Page 3: ...and foam detector and then you can open the cover of the siren to change the battery or make service without the siren sound The built in FLASH has five high brightness and low power LEDs which are sh...

Page 4: ...tage on this input drops bellow 5 8 V DC Activation from Trigger It is balanced when there are 0VDC on the Trigger input It sounds an alarm if the voltage of power supply is interrupted or if the volt...

Page 5: ...ACTIVATION INPUT 12V FOR FIRE ALARM SIGN INPUT 12V FOR AUDIBLE AND VISUAL VERIFICATION OF THE CONTROL PANEL STATUS TC INPUT 12V FOR TAMPER 3 AXIS ACCELEROMETER AND FOAM DETECTOR CANCELATION FLT OUT LO...

Page 6: ...nect the siren to the panel as explained in the connection terminals on page 5 and the following wiring diagram 6 When you finish cable connections connect the battery to the siren The siren can remai...

Page 7: ...emain open for only 10 seconds and then be deactivated If a fault is detected on the battery the FLT OUT output will remain activated after the end of 10 seconds and until the fault is restored Once t...

Page 8: ...here is a voltage at the siren power input 12V or every five minutes when there is no voltage If during the test the battery voltage is lower than 11 5V we have a low battery voltage indication and if...

Page 9: ...siren will follow If all the LEDs are off then the siren will have no lighting at standby mode To store this setting into memory press the MENU button The LED with the indication L S will turn on Sele...

Page 10: ...twenty four hours the duration of each alarm should be longer than 20 seconds Each time you press SELECT button you will hear the sound of the siren and will turn on or turn off all five LEDs of the...

Page 11: ...urns to standby mode after three minutes without pressing any of the two buttons This function allows you to open the siren for maintenance or to change the battery without the siren being activated b...

Page 12: ...e battery voltage is lower than this replace the battery and connect the new battery keeping in mind to use the correct polarity 4 Check for signs of water or insects entering the siren and clean if n...

Reviews: