SIGLENT
SPD3000 User Manual 29
Command format
SYSTem: STATus?
Description
Query the current working state of the equipment.
Instruction
The return info is
Hexadecimal format
, but the actual
state is
binary
, so you must change the return info into a
binary.
The state correspondence relationship is as
follow.
Example
SYSTem: STATus?
Return info
0x0224
Bit NO.
Corresponding state
0
0: CH1 CV mode; 1: CH1 CC mode
1
0: CH2 CV mode; 1: CH2 CC mode
2,3
01: Independent mode; 10: Parallel mode
11: Series mode
4
0: CH1 OFF 1: CH1 ON
5
0: CH2 OFF 1: CH2 ON
6
0: TIMER1 OFF 1: TIMER1 ON
7
0: TIMER2 OFF 1: TIMER2 ON
8
0: CH1 digital display; 1: CH1 waveform diplay
9
0: CH2 digital display; 1: CH2 waveform diplay
www.biall.com.pl