SIGLENT
SPD3000 User Manual 27
7.OUTPut
Command format
OUTPut <SOURce>, <state>
<SOURce>:={CH1 | CH2}; <state>:={ON | OFF}
Description
Turn on/off the specified channel.
Example
OUTPut CH1, ON
Command format
OUTPut: TRACK <NR1>
<NR1>:={
0
[Independent] |
1
[Series] |
2
[Parallel]}
Description
Select operation mode
Example
OUTPut: TRACK 0
Command format
OUTPut: WAVE<SOURce>, <state>
<SOURce>:={CH1 | CH2}; <state>:={ON | OFF}
Description
Turn on/off the Waveform Display function of specified
channel.
Example
OUTPut: WAVE CH1, ON
8.TIMEr
Command format
TIMEr: SET <SOURce>, <secnum>, <volt>, <curr>,
<time>
<SOURce>:={CH1 | CH2}; < secnum >;=1 to 5;
Description
Set timing parameters of specified channel
Example
TIMEr: SET CH1, 2, 3, 0.5, 2
www.biall.com.pl