Check hardware connections:
Make sure that all the boards are powered on.
If connecting over the network, switch to a direct serial connection (see the
section. The Panel Plus software will automatically recognize serial ports and list them in the drop-
down menu for available connections.
Connecting to the serial COM port on the 3000-OEM board from a host PC requires a null modem
adapter or null modem serial cable.
Check network configuration:
After communications have been established using the serial connection, networking settings can be
corrected to allow proper network communications.
1.
From the main menu, go to
Configure
»
Network Settings
.
2.
If an unknown static IP address is assigned, remove it, or update it to match the addressing scheme
of the current network.
Figure 14: Check Network Settings
8.2
3000-OEM HD-SDI Camera Input
Issue:
Network output video shows image in the upper left corner of Panel Plus with a green
background.
Check camera output settings:
The camera could be set to output 720P. The camera setting in
Acquisition
Settings
is set to 1080P.
Changing the camera to 720P in
Acquisition Setting
should correct this problem.
If the HD-SDI camera came with the EVAL kit, the camera resolution can be changed to 1080P30 using
the small controller joystick on the cable included in the kit.
The menus are easier to read if the yellow output of the camera (analog out) is connected to an
analog monitor.
Check network
settings