Specifications
* Universal flange fits ANSI, DIN, and JIS standards.
** Approximate shipping weight of transducer with standard cable length.
*** EMC performance available upon request.
XPS-10
XPS-15
XPS-30
XPS-40
XCT-8
XCT-12
Measurement
Range
0.3 - 10 m
(1 - 33 ft)
0.3 - 15 m
(1 - 50 ft)
0.6 - 30 m
(2 - 100 ft)
0.9 - 40 m
(3 -130 ft)
0.6 - 8 m
(2 - 26 ft)
0.6 - 12 m
(2 - 40 ft)
Frequency (kHz)
44
44
30
22
44
44
Beam Angle
12
6
6
6
12
6
Environmental
Location
indoor/outdoor indoor/outdoor
indoor/outdoor
indoor/outdoor
indoor/outdoor indoor/outdoor
Maximum
Altitude (m)
2000
2000
2000
2000
2000
2000
Ambient
Temperature
-40 to 95
C
(-40 to 203
F)
-40 to 95
C
(-40 to 203
F)
-40 to 95
C
(-40 to 203
F)
-40 to 95
C
(-40 to 203
F)
-40 to 145
C
(-40 to 293
F)
-40 to 145
C
(-40 to 293
F)
Pressure
8 bar
(120 psi)
8 bar
(120 psi)
Europe: 0.5 bar
N. America: 15 psi
Europe: 0.5 bar
N. America: 15 psi
8 bar
(120 psi)
8 bar
(120 psi)
Pollution Degree
4
4
4
4
4
4
Construction
Housing
PVDF
PVDF
PVDF
PVDF
Standard
: PVDF
Optional
: Universal* sized
flange available with PTFE
facing
Mounting
1" NPT or
BSP conduit
connection
1" NPT or BSP
conduit
connection
1-1/2" NPT or BSP
conduit
connection
1-1/2" NPT or BSP
conduit
connection
1" NPT or BSP
conduit
connection
1" NPT or BSP
conduit
connection
Options
•
factory bonded to suit ANSI, DIN, and JIS standards
•
polyethylene foam facing for dusty or steamy environments
•
submergence shield, where flooding can occur (available only for XPS-10,
XPS-15)
•
split flange for field mounting to suit ANSI, DIN, and JIS standards (not
available for XPS-40)
Cable
2-wire twisted pair/braided and
foil shielded, 0.5mm² (20 AWG),
PVC jacket
• 2-wire twisted pair/
braided and foil shielded,
0.5mm² (20 AWG), PVC
jacket
Maximum separation: 100 m
(330 ft)
• RG-62 A/U coax
Maximum separation: 365 m
(1200 ft)
Silicon Jacket
Weight**
0.8 kg
(1.7 lb)
1.3 kg
(2.8 lb)
4.3 kg
(9.5 lb)
8 kg
(18 lb)
0.8 kg
(1.7 lb)
1.3 kg
(2.8 lb)
Maximum
Separation
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
365 m
(1200 ft)
Supply Source
Transducers shall only be supplied by Siemens Milltronics certified controllers
Approvals
CE***, CSA, FM, CENELEC/ATEX, INMETRO: See nameplate or consult Siemens Milltronics for current
approvals.
Summary of Contents for XCT
Page 1: ...Ultrasonic Transducers Operating Instructions 03 2013 XPS XCT ...
Page 2: ......
Page 16: ...Page EN 14 XPS XCT Series Transducers OPERATION MANUAL A5E32282889 mmmmm English ...
Page 30: ...Side DA 14 XPS XCT Serie Transducere DRIFTSVEJLEDNING A5E32282889 Dansk ...
Page 44: ...Seite DE 14 Ultraschallsensoren XPS XCT BETRIEBSANLEITUNG A5E32282889 Deutsch ...
Page 58: ...Σελίδα EL 14 Μορφοτροπείς σειρών XPS XCT ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ A5E32282889 Ελληνικά ...
Page 72: ...Página ES 14 Sensores XPS XCT MANUAL DE OPERACIÓN A5E32282889 mmmmm Español ...
Page 86: ...Page FR 14 Transducteurs Série XPS XCT MANUEL D UTILISATION A5E32282889 mmmmm Français ...
Page 100: ...Pagina IT 14 Trasduttori serie XPS XCT MANUALE OPERATIVO A5E32282889 Italiano ...
Page 114: ...Pagina NE 14 XPS XCT serie transducers BEDIENINGSHANDLEIDING A5E32282889 Nederlands ...
Page 128: ...Página PT 14 Transdutores Séries XPS XCT MANUAL DE OPERAÇÃO A5E32282889 Português ...
Page 142: ...sivu SU 14 XPS XCT sarjan anturit KÄYTTÖOPAS A5E32282889 Suomi ...
Page 156: ...Sida SV 14 XPS XCT Transducerserier ANVÄNDNINGSMANUAL A5E32282889 Svenska ...