Connecting
5.3 Power supply options
Battery module
Check battery cable plug connection as shown in figure below.
The battery lifetime is highly dependent on thermal influences and consequently the
functioning period of the energy calculator can only be guaranteed if the max. ambient
temperature limits set out in section "Installation of device" (Page 17) are not exceeded.
Mounting battery
1.
Push battery into place in bottom section and press power supply cable into cut-out in top
of bottom section so that it is not crushed when refitting top of energy calculator (if not
done already).
2.
Mount plug on connection pin (if not done already).
3.
Refit top of energy calculator.
Used batteries must be disposed of at suitable collecting points.
230 V AC / 24 V AC module
Instead of a battery the power can be supplied from a 230 V AC or a 24 V AC power supply
module (depending on ordering).
Check cable plug connection of power supply module.
SITRANS FUE950
Operating Instructions, 01/2010, SFIDK.PS.022.F4.02
27