Technical data
11.5 Rated operating conditions
FC410 with Modbus
94
Operating Instructions, 02/2016, A5E33120874-AC
Table 11- 9 Additional error by deviations from reference conditions
Description
Specification
Sensor size
DN 15
DN 25
DN 50
DN 80
Effect of process pressure
[% of actual flowrate per bar]
±0.015
±0.015
±0.015
±0.015
Effect of process pressure at nominal flowrate
[(kg/h) per bar]
0.56
1.73
7.8
20.4
Effect of ambient temperature
[% / K actual flowrate]
Display/Frequency/Pulse output:
< ±0.003 < ±0.003 < ±0.003 < ±0.003
Effect of power supply fluctuations
None
None
None
None
Effect of media temperature [(kg/h)/°C]
±0.0875
±0.175
±1.05
±3.15
11.5
Rated operating conditions
Table 11- 10 Basic conditions
Description
Specification
Ambient temperature (°C[°F])
(Humidity max. 90 %)
Operation
-40 to +60 [-40 to +140]
Ambient temperature (°C[°F])
(Humidity max. 90 %)
Storage
-40 to +70 [-40 to +158]
Climate class
DIN 60721-3-4
Altitude
Up to 2000 m (6560 ft)
Relative humidity [%]
95
Bump resistance
On request
Shock resistance
On request
Thermal shock
On request
Vibration resistance
On request
EMC performance
EN/IEC 61326-1 (Industry)
Table 11- 11 Cleaning and sterilizing conditions
Description
Specification
Cleaning method
•
CIP
•
SIP
Cleaning temperature
On request
Cleaning frequency
On request
Cleaning duration
On request