8. Commissioning
Commissioning
SFIDK.PS.029.V3.02 -
521H0553
SITRANS F US SONOFLO
®
®
®
®
®
MASS FLOW
For SONO 3000 not fitted with a SENSORPROM
®
memory unit the display indication must be
formatted. It is done as follows:
a: Sensor
≤
DN 2000:
In the menu “MAX RANGE” the value 10 × “MASS FLOW MAX” should be entered.
b: Sensor > DN 2000:
In the menu “MAX RANGE” the value 5 × “MASS FLOW MAX” should be entered
(Max. 2 x 540.000 t/h).
User-defined relationship
In MASS FLOW select SCALED and density measuring unit, enter the two sets of data for sound
between sound velocity
velocity and density, mass flow measuring units and the maximum mass flow range. If the relay
and density
output is set to indicate sound limit, the relay will make if the actual sound velocity is outside the
range given by SOUND VELOCITY 1 and SOUND VELOCITY 2, i.e. indicating that the mass flow
is calculated with a density outside the defined range.
CRYOGENICS
Select cryogenic, mass flow measuring unit and the maximum mass flow range.
MASS FLOW
UNIT: ton/h
UNIT: lb/min
UNIT: lb/h
UNIT: kg/s
UNIT: kg/min
UNIT: kg/h
UNIT: ton/s
UNIT: ton/min
MASS FLOW
MAX. XXXX.XX
UUUUUU
DENSITY-2
XXXX.XXX
UUUUUU
SOUND VEL.-2
XXXX.UUUU
DENSITY-1
XXXX.XXX
UUUUUU
SOUND VEL.-1
XXXX.UUUU
DENSITY
UNIT: UUUUU
MASS FLOW
MASS FLOW
SCALED
MASS FLOW
CRYOGENIC [O2]
CRYOGENIC [N]
CRYOGENIC [AR]
OFF
MAX.
RANGE