Menu item
Parameter
Factory settings Options
More info
Output
Current output
Off for
MAG5000/
6000
On/off, Unidirectional/bidirectional, 0 to 20 mA/
4 to 20 mA/4 to 20 mA + Alarm
●
Alarm level
Low
High/Low
●
Alarm diff.
No
Yes/No
●
Time constant 5 s
0.1 to 30 s
Digital output
Pulse
Error, direction/limit, batch, frequency, pulse, er‐
ror number, off
Relay output
Error level
Error, direction/limit, cleaning, error number, off Error level
Direction/limit
switch
Off
1 setpoint, 2 setpoints
●
Setpoints
0%
-100 to +100%
●
Hysteresis
5%
0.0 to 100%
Batch
Off
●
Batch quantity 0
Sensor size dependent
●
Batch
compensation
0
-100 to +100 m
3
●
Batch counter Down
Up, down
Frequency
Off
500 Hz, 1 kHz, 5 kHz, 10 kHz
●
Time constant 5 s
0.1 to 30 s
Pulse
On
●
Pulse polarity
Positive
Positive, negative
●
Pulse width
66 ms
64 μs 130 μs, 260 μs, 510 μs, 1.0 ms, 2.0 ms,
4.1 ms, 8.2 ms, 16 ms, 33, ms, 66 ms, 130 ms,
260 ms, 520 ms, 1.0 s, 2.1 s, 4.2 s
●
Volume/pulse
Sensor size de‐
pendent
Dimension-dependent
●
Time constant 0.1 s
0.1 to 30 s
External input
External input
Off
Batch, reset totalizer, freeze output, forced out‐
put, off
●
Batch
Start
Start, hold/continue, stop, Qmax 2
Sensor charac‐
teristics
Correction factor
1
0.85 to 2.00
Language
Language
English
English, German, French, Danish, Swedish, Fin‐
nish, Spanish, Russian, Italian, Portuguese, Pol‐
ish
Factory settings
B.1 Transmitter factory settings