SITRANS F M MAGFLO
®
®
®
®
®
8
SFIDK.PS.026.E5.02
ENGLISH
2.5 Overview and
intrinsically safe data
Specifications:
Supply: 115-230 V or 24 V
Ambient temperature:
−
20 to 60
°
C
Enclosure: IP67/
NEMA 4X
2.
Installation
SENSOR INTERFACE
1. DN 6 - DN 300 mm
Certificate: Sira 03ATEX1503X
II 2(1)(2) G D
Remote version:
EEx d [ia] ia [ib] ib IIB T6 /
Compact version:
EEx d [ia] [ib] IIB T6
2.5.1 Transmitter data
MAG 6000 I (Ex d)
Electrode
81,82,83,84
IIB
IIC
U
o
30 V
30 V
I
o
6.1 mA
6.1 mA
C
o
66 nF
560 nF
L
o
0.96 H
0.96 H
P
o
45.5 mW
45.5 mW
! Coil terminal 85, 86 are “e” terminals.
2. DN 350 - 2000 mm
Certificate: Sira 05ATEX2072X
II 2(1)(2) G D
Remote version:
EEx d e [ia] ia [ib] ib IIC T6 /
Compact version:
EEx d [ia] [ib] IIC T6
User I/O INTERFACE
DN 6 - DN 300
Certificate: Sira 03ATEX1503X
II 2(1)(2) G D
Remote version:
EEx d [ia] ia [ib] ib IIB T6 /
Compact version:
EEx d [ia] [ib] IIB T6
DN 350 - DN 2000
Certificate: Sira 05ATEX2072X
II 2(1)(2) G D
Remote version:
EEx d e [ia] ia [ib] ib IIC T6 /
Compact version:
EEx d [ia] [ib] IIC T6
Electrode
Coil
81,82,83,84
85,86
IIB
IIC*
IIB
IIC*
U
o
30 V
U
o
30 V
I
o
6.1 mA
I
o
105 mA
C
o
560 nF
C
o
60 nF
L
o
1 H
L
o
2.07 mH
P
o
45.5 mW
P
o
3.3 W
* N/A