SITRANS F M MAGFLO
®
®
®
®
®
22
SFIDK.PS.026.E5.02
ENGLISH
4.
Technical data
Current output
Current
0-20 mA, 4-20 mA or 4-20 mA + alarm
(Active or
Load
<
560 ohm
passive)
Time constant
0.1-30 s adjustable
Ex-version Passive default / Non Ex-version Active default
Digital output
Frequency
0-10 kHz, 50% duty cycle
Time constant
0.1-30 s adjustable
Passive
3-30 V DC, 1 K
Ω
≤
R
load
≤
10 K
Ω
Ex output characteristics
Refer to section 2.5
(Terminals: 56-57)
Relay
Time constant
Changeover relay, time constant same as current time constant
Load
42 V AC/2 A, 24 V DC/1A
Ex output characteristics
Refer to section 2.5
(Terminals: 31-32)
Digital input
11-30 V DC, R
i
= 4.4 K
Ω
Activation time
50 ms
Current
I
11 V DC
= 2.5 mA, I
30 V DC
= 7 mA
Functions
Flow rate, 2 totalizers, low flow cut-off, empty pipe cut-off, flow
direction, error system, operating time, uni/bidirectional flow, limit
switches, pulse output
Galvanic isolation
All inputs and outputs are galvanically isolated
Cut-off
Low flow
0-9.9% of maximum flow
Empty pipe
Detection of empty pipe
1
)
Totalizer
Two eight-digit counters for forward, net or reverse flow
Display
Background illumination with alphanumerical text, 3 × 20 characters
to indicate flow rate, totalized values, settings and faults
Reverse flow indicated by negative sign
Time constant
Time constant as current output time constant
Zero point adjustment
Automatic
Electrode input impedance
>
1 x 10
14
Ω
Excitation frequency
Sensor size depending pulsating DC current
Ambient temperature
Display version during operation:
−
20 to +60
°
C
During storage:
−
40 to +70
°
C (RH max. 95%)
Communication
Standard
Prepared for customer mounted add-on modules
Optional
HART, Profibus PA on Ex version
Compact
Enclosure material
Die cast Aluminium, painted
Enclosure rating
IP67/NEMA 4X to EN 60529 and DIN 40050 (1 m w.g. for 30 minutes)
Mechanical load
18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-36
EMC performance
EN 61326
Supply voltage
MAG 6000 I:
18-90 V DC / 115-230 V AC
MAG 6000 I (Ex d):
115-230 V AC or 18-30 V DC
Power consumption
230 V AC: 21,5 VA
24 V DC: 12 W, I
N
= 380 mA, I
ST
= 1A (3 ms)
Profibus PA
Refer to section 2.5
(Terminals: 95-96)
4.3 Transmitter type
MAG 6000 I
Accuracy 0.25%
1
) Special cable required in separate mounted installation