SITRANS F M MAGFLO
®
®
®
®
®
35
SFIDK.PS.026.E5.02
ENGLISH
5.5.
Settings available
Parameter
Factory settings
Settings available
Password
Default value
1000
Password
1000
1000 - 9999
Basic settings
Flow direction
Positive
Positive, negative
Q
max.
Dim. dependent
Dim. dependent
- Volume units
Dim. dependent
m
3
, ml, l, kl, hl, Ml, ft
3
, in
3
, USG, USkG, USMG, UKG,
UKMG, USBBL
-
Time units
Dim. dependent
Sec., min., hour, day
Totalizer 1
Forward
Forward, reverse, net
- Totalizer 1 units
Dim. dependent
m
3
, ml, l, kl, hl, Ml, ft
3
, in
3
, USG, USkG, USMG, UKG,
UKMG, USBBL
Totalizer 2
Reverse
Forward, reverse, net
- Totalizer 2 units
Dim. dependent
m
3
, ml, l, kl, hl, Ml, ft
3
, in
3
, USG, USkG, USMG, UKG,
UKMG, USBBL
Low flow cut-off
1.5 %
0 - 9.9 %
Empty pipe
Off
Off, on
Error level
Warning
Fatal, permanent, warning
Output
Current output
Off
On/off, uni-/bidirectional, 0/4 - 20 mA
- Time constant
5 s
0.1 - 30 s
Digital output
Pulse
Error, direction/limit, batch, frequency, pulse, error
no., off
Relay output
Error
Error, direction/limit, cleaning, error No., off
Direction/limit switch
Off
1 set point/2 set points,
−
100 - 100%
- Hysteresis
5%
0.0 - 100%
Batch
Off
- Batch quantity
0
Dim. dependent
- Batch compensation
0
−
100 - 100 m
3
- Batch counter
Down
Up/down
- Time constant
0.1 s
0.1 - 30 s
Frequency
Off
500 Hz, 1 kHz, 5 kHz, 10 kHz
- Time constant
5 s
0.1 - 30 s
Pulse
On
- Pulse polarity
Positive
Positive/negative
- Pulse width
66 ms
64 µs, 130 µs, 260 µs, 510 µs, 1.0 ms, 2.0 ms,
4.1 ms, 8.2 ms, 16 ms, 33 ms, 66 ms, 130 ms,
260 ms, 520 ms, 1.0 s, 2.1 s, 4.2 s.
- Volume/pulse
Dim. dependent
Dim. dependent
- Time constant
0.1 s
0.1 - 30 s
Electrode cleaning
Off
Off/cleaning
- Cleaning cycle time
24 h
1 - 240 h
External input
External input
Off
Batch, reset totalizer, freeze output, forced output, off
- Batch
Start, hold/continue, stop, Q
max.
2
Sensor characteristics
Correction factor
1
0.85 - 2.00
Language
English
English, German, French, Danish, Swedish, Finnish,
Spanish, Russian, Italian, Portuguese and Polish
Operator menu
Primary field
Flow rate
Flow rate, Totalizer 1, Totalizer 2
Title/subtitle line
Flow rate
Flow rate, Flow rate %, Q
max.
, Totalizer 1, Totalizer 2,
Totalizer 1 reset, Totalizer 2 reset, Batch start/
paused/stop, Batch cycle counter, Batch cycle
counter reset, Sensor size, Sensor type, Error
pending, Status log, Tag No.
The transmitter is delivered with factory settings ready to measure the actual flow.
5.
Commissioning