SITRANS F M MAGFLO
®
®
®
®
®
10
SFIDK.PS.026.E5.02
ENGLISH
Example label, transmitter
type MAG 6000 I (Ex d)
compact
2.
Installation
Data not for reference
2.7 Ex approvals
MAG 1100 Ex
DN 6 - DN 100
SIRA 03 ATEX 1423X CE 0518
II 2 (1)(2) G
EEx [ia] [ib] IIB T4...T6,
Temperature ratings are as follows*:
T4 (max. surface < 135°C) for liquid temperatures lower than 100°C
T5 (max. surface < 100°C) for liquid temperatures lower than 82°C
T6 (max. surface < 85°C) for liquid temperatures lower than 67°C
For an ambient temperature of –20°C to + 50°C
MAG 3100 Ex
DN 15 - DN 300
SIRA 03 ATEX 1442X CE 0518
II 2 (1)(2) G
EEx d [ia] [ib] IIB T4...T6,
Temperature ratings are as follows*:
T4 (max. surface < 135°C) for liquid temperatures lower than 100°C
T5 (max. surface < 100°C) for liquid temperatures lower than 87°C
T6 (max. surface < 85°C) for liquid temperatures lower than 72°C
For an ambient temperature of –20°C to +50°C
MAG 3100 Ex
DN 350 - DN 2000
SIRA 03 ATEX 3339X CE 0518
II 2 GD IP65 T(**)
O
C
EEx e ia IIC T3…T6,
where (**) represents the pipeline tempe 5K for dust approval
Temperature ratings are as follows*:
T3 (max. surface < 200°C) for liquid temperatures lower than 190°C
T4 (max. surface < 135°C) for liquid temperatures lower than 125°C
T5 (max. surface < 100°C) for liquid temperatures lower than 90°C
T6 (max. surface < 85°C) for liquid temperatures lower than 75°C
For an ambient temperature of –20°C to +40°C
MAG 6000 I (Ex d)
For use with
MAG 3100 Ex sizes DN 15 - DN 300
For use with
MAG 1100 Ex (all sizes)
For compact and remote mounting DN 6 - DN 300:
SIRA 03 ATEX 1503X
II 2 (1) (2) G D
Remote version:
EEx d [ia] ia [ib] ib IIB T6 /
Compact version:
EEx d [ia] [ib] IIB T6
For use with
MAG 3100 Ex sizes DN 350 - DN 2000
SIRA 03 ATEX 2072X
II 2 (1) (2) G D
EEx d e [ia] ia [ib] ib IIC, T6
Remote version:
EEx d e [ia] ia [ib] ib IIC T6 /
Compact version:
EEx d [ia] [ib] IIC T6
* Temperature ratings may be limited by the lining selected, see section 4.