Display mode functions
41
Siemens Building Technologies
Fire Safety & Security Products
01.2008
Fig. 19
Display reference image
The menu option remains inactive if no reference frame has been stored or the
user does not have adequate authority.
On SISTORE MX RemoteView, this menu option is always enabled if the user has
authorisation to display a reference frame. If no reference image has been saved
for the selected camera, an information message is displayed.
10.10 Output of video image on analog monitor
Each video image can be displayed on an analog monitor provided that it was
captured by an analog camera. This can be done by clicking the right mouse
button being in the corresponding camera picture and then selecting „Monitor“ from
the context menu. The automatic output of all camera pictures on an analogue
monitor can be activated or deactivated via the menu
View
->
Cameras on
monitor
, or by selecting the appropriate button on the toolbar.
If an alarm occurs where the images of a specific camera are to be switched to the
monitor in compliance with configuration, that camera has priority over manual
selection. The automatic picture sequence is interrupted for the duration of event.
10.11 Display camera group
If more cameras are released for display than can be displayed simultaneously in a
multiple split screen, all cameras are divided into groups. SISTORE MX defines
these groups independently. The first
n
camera windows are located in Group 1,
the last camera windows to be displayed are in the last group. The groups may be
switched through either manually or in an automatic sequence. The groups are
shown in order, with the first group being shown again after the last group.
The selection of either manual or automatic switching through is carried out via the
menu
View
->
Next Display Group
or
Automatic Scan
, or directly by selecting
the appropriate button in the toolbar. During the enlarged display of a window,
switching through camera groups is not possible.