Appendix
A.9 Information List
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
383
3581
Remote signal 9 received
(Rem.Sig 9 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
166
1
Yes
3582
Remote signal 10 received
(Rem.Sig 10 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
167
1
Yes
3583
Remote signal 11 received
(Rem.Sig 11 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
168
1
Yes
3584
Remote signal 12 received
(Rem.Sig 12 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
169
1
Yes
3585
Remote signal 13 received
(Rem.Sig 13 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
170
1
Yes
3586
Remote signal 14 received
(Rem.Sig 14 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
171
1
Yes
3587
Remote signal 15 received
(Rem.Sig 15 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
172
1
Yes
3588
Remote signal 16 received
(Rem.Sig 16 Rx)
Remote Signals
OUT
On
Off
*
*
LED
BO
93
173
1
Yes
4403
>BLOCK Direct Transfer Trip
option (>BLOCK DTT)
DTT Direct Trip
SP
*
*
*
LED BI
BO
4417
>Direct Transfer Trip INPUT
Phases ABC (>DTT Trip ØABC)
DTT Direct Trip
SP
On
Off
*
*
LED BI
BO
4421
Direct Transfer Trip is switched
OFF (DTT OFF)
DTT Direct Trip
OUT
On
Off
*
*
LED
BO
51
21
1
Yes
4422
Direct Transfer Trip is BLOCKED
(DTT BLOCK)
DTT Direct Trip
OUT
On
Off
On
Off
*
LED
BO
51
22
1
Yes
4435
DTT TRIP command Phases
ABC (DTT TRIP ØABC)
DTT Direct Trip
OUT
*
ON
*
LED
BO
51
35
2
No
5203
>BLOCK 81O/U (>BLOCK
81O/U)
81 O/U Freq.
SP
On
Off
*
*
LED BI
BO
70
176
1
Yes
5206
>BLOCK 81-1 (>BLOCK 81-1)
81 O/U Freq.
SP
On
Off
*
*
LED BI
BO
70
177
1
Yes
5207
>BLOCK 81-2 (>BLOCK 81-2)
81 O/U Freq.
SP
On
Off
*
*
LED BI
BO
70
178
1
Yes
5208
>BLOCK 81-3 (>BLOCK 81-3)
81 O/U Freq.
SP
On
Off
*
*
LED BI
BO
70
179
1
Yes
5209
>BLOCK 81-4 (>BLOCK 81-4)
81 O/U Freq.
SP
On
Off
*
*
LED BI
BO
70
180
1
Yes
5211
81 OFF (81 OFF)
81 O/U Freq.
OUT
On
Off
*
*
LED
BO
70
181
1
Yes
5212
81 BLOCKED (81 BLOCKED)
81 O/U Freq.
OUT
On
Off
On
Off
*
LED
BO
70
182
1
Yes
5213
81 ACTIVE (81 ACTIVE)
81 O/U Freq.
OUT
On
Off
*
*
LED
BO
70
183
1
Yes
5215
81 Undervoltage Block (81
UnderV Blk)
81 O/U Freq.
OUT
On
Off
On
Off
*
LED
BO
70
238
1
Yes
5232
81-1 picked up (81-1 picked up)
81 O/U Freq.
OUT
*
On
Off
*
LED
BO
70
230
2
Yes
5233
81-2 picked up (81-2 picked up)
81 O/U Freq.
OUT
*
On
Off
*
LED
BO
70
231
2
Yes
5234
81-3 picked up (81-3 picked up)
81 O/U Freq.
OUT
*
On
Off
*
LED
BO
70
232
2
Yes
5235
81-4 picked up (81-4 picked up)
81 O/U Freq.
OUT
*
On
Off
*
LED
BO
70
233
2
Yes
5236
81-1 TRIP (81-1 TRIP)
81 O/U Freq.
OUT
*
ON
*
LED
BO
70
234
2
Yes
5237
81-2 TRIP (81-2 TRIP)
81 O/U Freq.
OUT
*
ON
*
LED
BO
70
235
2
Yes
5238
81-3 TRIP (81-3 TRIP)
81 O/U Freq.
OUT
*
ON
*
LED
BO
70
236
2
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on