Appendix
A.9 Information List
SIPROTEC, 7SC805, Manual
C53000-G1140-C380-1, Release date 05.2014
146
160
Alarm Summary Event (Alarm
Sum Event)
Device, General
OUT
On
Off
*
*
LED
BO
160
46
1
Yes
177
Failure: Battery empty (Fail Bat-
tery)
Device, General
OUT
On
Off
*
*
LED
BO
178
I/O-Board Error (I/O-Board error) Device, General
OUT
On
Off
*
*
LED
BO
191
Error: Offset (Error Offset)
Device, General
OUT
On
Off
*
*
LED
BO
193
Alarm: NO calibration data avail-
able (Alarm NO calibr)
Device, General
OUT
On
Off
*
*
LED
BO
320
Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device, General
OUT
On
Off
*
*
LED
BO
321
Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
Device, General
OUT
On
Off
*
*
LED
BO
322
Warn: Limit of Memory Operation
exceeded (Warn Mem. Oper.)
Device, General
OUT
On
Off
*
*
LED
BO
323
Warn: Limit of Memory New ex-
ceeded (Warn Mem. New)
Device, General
OUT
On
Off
*
*
LED
BO
335
>GOOSE-Stop (>GOOSE-Stop)
Device, General
SP
On
Off
*
LED BI
FC
TN
BO
356
>Manual close signal (>Manual
Close)
P.System Data 2
SP
*
*
*
LED BI
BO
150
6
1
Yes
373.3001
Hot Line Tag internal trigger
(HotLineTag int.)
Device, General
IntSP
On
Off
*
LED
BO
373.3002
Hot Line Tag external trigger
(HotLineTag ext.)
Device, General
IntSP
On
Off
*
LED
BO
420
>Opened Control device 2
(>Opened Ctrl 2)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
421
>Opened Control device 3
(>Opened Ctrl 3)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
422
>Closed Control device 2
(>Closed Ctrl 2)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
423
>Closed Control device 3
(>Closed Ctrl 3)
P.System Data 2
SP
On
Off
*
*
LED BI
BO
424
Open control device 2 (Open Ctrl
2)
P.System Data 2
OUT
On
Off
*
*
LED
BO
425
Close control device 2 (Close Ctrl
2)
P.System Data 2
OUT
On
Off
*
*
LED
BO
426
Open control device 3 (Open Ctrl
3)
P.System Data 2
OUT
On
Off
*
*
LED
BO
427
Close control device 3 (Close Ctrl
3)
P.System Data 2
OUT
On
Off
*
*
LED
BO
533
Primary fault current Ia (Ia =)
P.System Data 2
VI
On
Off
150
177
4
No
534
Primary fault current Ib (Ib =)
P.System Data 2
VI
On
Off
150
178
4
No
535
Primary fault current Ic (Ic =)
P.System Data 2
VI
On
Off
150
179
4
No
561
Manual close signal detected
(Man.Clos.Detect)
P.System Data 2
OUT
On
Off
*
*
LED
BO
1020
Counter of operating hours
(Op.Hours=)
Statistics
VI
2172
GPS Module Error (GPS Modu-
leError)
Device, General
OUT
On
Off
*
LED
BO
2186
Error occurred on IO board (Error
IO board)
Device, General
OUT
On
Off
*
*
LED
BO
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on