![Siemens SIMATIC VS130 Series Manual Download Page 71](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431071.webp)
Appendix
Vision Sensor VS 130
A5E00199459-01
A-7
Mechanical Environmental Conditions for Operation
Test for / Test standard
Remarks
Shock test
complying with
IEC 60068-2-29
•
Type of shock: half sine
•
Strength of the shock:
-
Processing unit: 10 g peak value / 16 ms duration
-
Sensor head, illumination: 10 g peak value / 16 ms duration
•
Direction of shock: 100 shocks in each of the 3 perpendicular axes
Shock
Shock test
complying with
IEC 60068-2-27
Sensor head, illumination:
•
70 g peak value / 6 ms duration 3 times in each direction
•
30 g peak value / 11 ms duration 3 times in each direction
Climatic Environmental Conditions for Operation
Environmental Conditions Permitted Range
Note
Temperature
0 to +50
°
C
Temperature change
Max. 10
°
C/h
Relative humidity
Max. 95 % at +25
°
C
No condensation,
corresponds to
relative humidity
degree 2 to
IEC 61131-2
Air pressure
1080 to 795 hPa (corresponds to a height of
-1000 to 2000 m)
Contaminant concentration
•
SO
2
: < 0.5 ppm;
RH < 60 %, no condensation
•
H
2
S: < 0.1 ppm;
RH < 60 %, no condensation
•
Test: 10 ppm;
4 days
•
Test: 1 ppm;
4 days
Note
The mechanic and climatic ambient conditions specified above for operation are
valid for only sensor heads with order numbers 6GF2 002-8DA and
6GF2 002-8EA.
The mechanic and climatic ambient conditions for the sensor head with order
number 6GF2 002-8CA depend on the lens used.
Test voltages to IEC 61131-2
Circuits with rated voltage U
e
to other circuits or ground
Test voltage
0 V < U
e
≤
50 V
350 V
50 V < U
e
≤
100 V
700 V
100 V < U
e
≤
150 V
1300 V
150 V < U
e
≤
300 V
2200 V