![Siemens SIMATIC VS130 Series Manual Download Page 29](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431029.webp)
Putting into Operation
Vision Sensor VS 130
A5E00199459-01
4-3
Description of the LEDs
LED
Function
SF
Group error
POWER
Power supply turned on
TRAINED
Trained:
•
In
Run:
-
0 = selected code has not been trained
-
1 = selected code has been trained
•
In Training (TRN=1):
-
0 = training active
-
1 = acknowledgment signal (RDY=0)
READY
Ready:
•
0 = device startup or SIMATIC VS 130 in Stop
•
1 = SIMATIC VS 130 in Run
READ
Result of evaluation: Code was localized and decoded. The LED is lit
when the corresponding output signal changes.
MATCH
Result of evaluation: Code matches learned code. The LED is lit when the
corresponding output signal changes.
N_OK
Code was not legible.
BF
Bus error on PROFIBUS
Setting Numeric Values
You select the places of a value with the arrow buttons " " and " ".
You change the value of a place in the number with the arrow buttons "
▲
" and "
▼
".
The speed at which the numeric value changes depends on how long you press
the arrow buttons. As soon as you release the arrow buttons, the rate of change
returns to the slowest level again.