![Siemens SIMATIC VS130 Series Manual Download Page 69](http://html.mh-extra.com/html/siemens/simatic-vs130-series/simatic-vs130-series_manual_374431069.webp)
Appendix
Vision Sensor VS 130
A5E00199459-01
A-5
A.2.2 General
Data
Power Supply
Supply voltage (U
N
)
•
Input voltage protected
against polarity reversal
•
Voltage loss (can be
bridged)
DC24 V; (DC20.4...DC28.8 V, safety extra-low voltage SELV).
SIMATIC VS 130 does not have integrated protection against surge in
the
µ
s range. For external measures, see EMC.
Yes
≥
20 ms
Current consumption (I
N
)
typically: I = 2 A (maximum load of 1.5 A over the digital inputs/outputs)
Fuse
max. 10 A
Making current
1
max. 10 A; < 1 ms
Safety requirements complying
with
IEC 61131-2 corresponds to DIN EN 61131-2
Electromagnetic Compatibility (EMC)
Pulse-shaped interference
Interference
Test voltage
Corr. to
severity
Electrostatic discharge
according to IEC 61000-4-2
•
Discharge in air:
±
8 kV
•
Contact
discharge:
±
6 kV
3
Burst pulse (fast transients)
complying with IEC 61000-4-4
•
2 kV (power supply cable)
•
2 kV (signal line)
3
Surge complying with IEC 61000-4-5
Coupling
Test voltage
Corr. to
severity
Asymmetrical
2 kV (power supply cable) direct voltage with protective
elements
3
Symmetrical
1 kV (power supply cable) direct voltage with protective
elements
3
Sine-shaped disturbance
Radio frequency
electromagnetic fields
Test values
Corr. to
severity
complying with IEC 61000-4-3
10 V/m at 80 % amplitude modulation of 1 kHz in the
range from 80 MHz to 1000 MHz
3
complying with IEC 61000-4-3
10 V/m at 50 % pulse modulation at 900 MHz
3
RF interference on
cable/cable shields
Test values
Corr. to
severity
complying with IEC 61000-4-6
Test voltage 10 V at 80 % amplitude modulation of
1 kHz in the range from 9 kHz to 80 MHz
3