Operator Functions
Vision Sensor VS 130
5-8
A5E00199459-01
Display
Description
Adjust All
N_OK
OK:Finish
•
1st line: The mode "Evaluate all images" is set (Note: this is the default.).
•
2nd line: The code could not be localized (and therefore not read).
•
4th line: By pressing "OK", you exit the adjust mode.
Note
If the processing unit has a connection to a PC with setup software, and you have
deactivated the "Read" check box in the "Options" group, the second and third
lines of the display field in the last two displays remain empty, since in this case,
there is no code localization.
No Connection to PC with Setup Software
After evaluating approximately 20 images or when you press the arrow buttons
or , the following display appears for approximately two seconds (this is called
the toggle display):
Display
Description
Use
↑
and
↓
to
toggle TRG
and ALL
With the arrow buttons
▲
and
▼
, you switch between the modes "Evaluate all
images" and "Image capture only on trigger signal".
In the "Image capture only on trigger signal" mode, the display appears, for
example as shown below:
Display
Description
Adjust TRG
Read
√
X:+6 Y:-1
OK:Finish
The "Image capture only on trigger signal" is indicated by "TRG".
After capturing approximately 20 (triggered) images or when you press the arrow
buttons or the toggle display appears again.
Connection to PC with Setup Software
If you want to change over between the modes "Evaluate all images" and "Image
capture only on trigger signal", you do this with the "Triggered only" check box in
the "Options" group of the setup software (see Section A.7.3).
Note
If the connection between the processing unit and PC with the setup software is
interrupted, the same applies as explained in "No connection to PC with setup
software".