102BTechnology instructions
9.3 Basic motion control
S7-1200 Programmable controller
System Manual, 11/2011, A5E02486680-05
345
Configure the properties for the drive signals, drive
mechanics, and position monitoring (hardware and
software limit switches).
Do not deselect the options for a hardware limit or
a reference point configuration unless the input
point is no longer assigned as a hardware limit or a
reference point.
You configure the motion dynamics and the
behavior of the emergency stop command.
You also configure the homing behavior (passive and active).
Use the "Commissioning" control panel to test the functionality independently from your user
program.
Click the "Startup" icon to commission the axis.
The control panel shows the current status of the axis. Not only can you enable and disable
the axis, but you can also test the positioning of the axis (both in absolute and relative terms)
and can specify the velocity, acceleration and deceleration. You can also test the homing
and jogging tasks. The control panel also allows you to acknowledge errors.