7.4.2
6ES5 760 Terminator
The IM 314 of the last expansion unit of each run is terminated with
the 6ES5 760-1AA11 terminator. The IM 312 and IM 301-3 (with a
free centralized connection) is terminated with the 6ES5 760-0AB11
terminator. The IM 301-3 (with a free distributed connection) is
terminated with the 6ES5 760-0AA11 terminator.
1
17
34
50
6
22
5
12
6ES5 760 - 0AB11
6ES5 760 - 0AA11
8
9
6
7
4
5
2
3
24
25
22
23
20
21
18
19
12
13
10
11
30
31
28
29
26
27
46
47
44
45
42
43
38
39
34
35
36
37
40
41
14 / 48
16
50
15 / 49
6ES5 760 - 1AA11
8
9
6
7
4
5
2
3
24
25
22
23
20
21
18
19
12
13
10
11
30
31
28
29
26
27
46
47
44
45
42
43
38
39
34
35
36
37
40
41
48
49
15
16
14
50
1)
1)
1)
1)
2)
1) 100 ohms
2) 200 ohms
Connector
Pin
180-ohm Resistor
or Jumper
180-ohm Resistor
or Jumper
Connector
Pin
Connector
Pin
Connector
Pin
Connector
Pin
Connector
Pin
180-ohm Resistor
or Jumper
Figure 7-16
Pin Assignments of the 760 Terminator
Technical Specifications
System Manual
7 - 24