SIMATIC PN/J1939 LINK
Operating Instructions, 12/2018, A5E45307564-AA
63
Technical specifications
12
12.1
Technical specifications of the PN/J1939 LINK
Technical specifications of PN/J1939 LINK
Article number
6BK1623-0AA00-0AA0
General information
Product type designation
PN/J1939 LINK
Firmware version
V1.0
•
FW update possible
Yes
Vendor identification (VendorID)
0x002A
Product function
•
I&M data
Yes
•
Isochronous mode
No
Installation type/mounting
Mounting
DIN rail, wall mounting, portrait mounting
Mounting position
Any
Recommended mounting position
Horizontal
Supply voltage
Type of supply voltage
24 V DC
Rated value (DC)
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Reverse polarity protection
Yes
Overvoltage protection
Yes
Short-circuit protection
Yes
Mains buffering
•
Mains/voltage failure stored energy time
10 ms; PN side
Input current
Current consumption (rated value)
0.09 A
Current consumption, max.
0.11 A
Power loss
Power loss, typ.
2.2 W
Engineering with
STEP 7 V14 SP1
•
STEP 7 TIA Portal
configurable/integrated
a
s of version
Summary of Contents for SIMATIC PN/J1939 LINK