4.3
TP ports (twisted pair)
RJ-45 connector pinout
With SCALANCE X-000, the twisted-pair ports are designed as RJ-45 jacks with MDI-X pin
assignment (Medium Dependent Interface Autocrossover) of a network component.
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
Note
Permitted cable lengths
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the TP port with
RJ-45 jacks.
With the IE FC cables and IE FC RJ-45 plugs 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.
Autonegotiation
With the autonegotiation mechanism, repeaters and end devices can automatically determine
the transmission speed and the transmission mode of the partner port. This makes it possible
to configure different devices automatically.
Description of the device
4.3 TP ports (twisted pair)
SCALANCE X-000
Operating Instructions, 12/2018, C79000-G8976-C344-03
17
Summary of Contents for SIMATIC NET SCALANCE X-000 Series
Page 4: ...Table of contents SCALANCE X 000 4 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Page 10: ...Safety notices SCALANCE X 000 10 Operating Instructions 12 2018 C79000 G8976 C344 03 ...
Page 12: ...Network topologies SCALANCE X 000 12 Operating Instructions 12 2018 C79000 G8976 C344 03 ...