Technical specifications
Ambient temperature
During operation
-40 ℃ to +75 ℃
During storage
-40 ℃ to +80 ℃
During transportation
-40 ℃ to +80 ℃
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 46 ℃ ambient temper‐
ature
≤ 2,000 m above sea level at max. 40 ℃ ambient temper‐
ature
Design, dimensions and weight
Immunity
EN 61000-6-2
EN 61000-6-1
RF interference level
EN 61000-6-4
Degree of protection
IP30
MTBF (EN/IEC 61709, 40 °C)
165 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover
Polyphenylene ether + polystyrene (PPE+PS plastic)
Weight
550 g
Dimensions (W x H x D)
44 x 125 x 124 mm
Installation options
● Mounting on a DIN rail
● Mounting on an S7-300 standard rail
● Wall mounting
Switching properties
Aging time
45 seconds
Max. number of learnable MAC ad‐
dresses
1024
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Yes
Maximum frame size
1536 bytes
Forwarding of PRP frames (Parallel
Redundancy Protocol)
Yes
Technical specifications
SCALANCE X-000
38
Operating Instructions, 12/2018, C79000-G8976-C344-03