3. Release the DIN rail catch on the bottom of the device using a screwdriver.
4. Pull the lower part of the device away from the DIN rail.
Figure 5-2
Removal from a 35 mm DIN rail
5.4
Installation on a standard rail
Installation on a SIMATIC S7-300 standard rail
To install the device on an S7-300 standard rail, follow the steps below:
1. Place the first housing guide of the device on the top edge of the S7-300 standard rail.
2. Screw the device to the underside of the standard rail (tightening torque 2 Nm).
3. Fit the connectors for the power supply. See also section "Power supply (Page 29)".
4. Insert the terminal block for the power supply into the socket on the device.
Mounting
5.4 Installation on a standard rail
SCALANCE X-000
24
Operating Instructions, 12/2018, C79000-G8976-C344-03