Configuration
5.4 Configuring the telecontrol instructions
CP 1242-7
Operating Instructions, 09/2011, C79000-G8976-C247-02
71
Parameter
Data type
Initial value
Description
Mode
UINT
Validity (1: permanent, 2: temporary)
Provider [1...5]
ARRAY [1...5]
of STRING [8]
Alternative GSM networks with priority 1 to 5 into which
the CP dials. Up to 5 networks can be configured. No. 1
with highest priority, no. 5 with lowest priority.
Entry of the Public Land Mobile Network (PLMN) of the
network provider consisting of Mobile Country Code
(MCC) and Mobile Network Code (MNC).
Example (test network of Siemens AG): 26276
Field for the "DNS configuration" parameter area
Table 5- 16 IF_CONF_DNS
Parameter
Data type
Initial value
Description
Id
UINT
16
ID of the parameter field
Length
UINT
Length of the parameter field in bytes: 14
Mode
UINT
Validity (1: permanent, 2: temporary)
DNS_IP [1]
IP_V4
IP address of the 1st domain name system server
DNS_IP [2]
IP_V4
IP address of the 2nd domain name system server
Field for the "Time-of-day synchronization" parameter area
Table 5- 17 IF_CONF_NTP
Parameter
Data type
Initial value
Description
Id
UINT
17
ID of the parameter field
Length
UINT
Length of the parameter field in bytes: 24
Mode
UINT
Validity (1: permanent, 2: temporary)
NTP_IP [1]
ARRAY [1...4]
of IP_V4
IP address of NTP server 1
...
...
(IP address of NTP server 2...3)
NTP_IP [4]
ARRAY [1...4]
of IP_V4
IP address of NTP server 4