Technical Specifications
5.3 Operating Environment
5.3
Operating Environment
The RUGGEDCOM RX1501 is rated to operate under the following environmental
conditions.
Note
Temperature limits for select line modules may differ from that which can be
withstood by the RUGGEDCOM RX1501. Make sure the selected modules are
rated for the expected environmental conditions before deployment. For more
information, refer to the "RUGGEDCOM RX1501 Series Modules Catalog".
Ambient Operating
Temperature
-40 to 85 °C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85 °C (-40 to 185 °F)
5% to 95%
Maximum Altitude
12192 m (40000 ft)
Maximum ambient operating temperature is 70 °C (158 °F) when the device is installed along with
Underwriter Laboratories (UL) listed devices.
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
Operating temperature may vary based on the limitations of installed SFPs. Refer to the "RUGGEDCOM
SFP Transceivers Catalog" for SFP temperature ratings.
Non-condensing.
5.4
Mechanical Specifications
Weight
Approximately 4.7 kg (10.3 lb)
Ingress Protection
IP30
Enclosure
Aluminum
5.5
Dimension Drawings
Note
All dimensions are in millimeters, unless otherwise stated.
36
RUGGEDCOM RX1501
Installation Manual, 10/2021, C79000-G8976-1054-21