background image

Dimension drawings 

 

9.2 Dimension drawings of SIMATIC IPC627E (5 expansion slots) 

 

SIMATIC IPC627E 

128

 

Operating Instructions, 12/2018, A5E44297201-AA 

Dimension drawing for installation with the vertical mounting kit for PC port access from the 

front 

 

All dimensions in mm 

Summary of Contents for SIMATIC IPC627E

Page 1: ...IC Industrial PC SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA Preface Product description 1 Safety instructions 2 Installing and connecting the device 3 Commissioning the device 4 Operating the device 5 Expanding and assigning parameters to the device 6 Device maintenance and repair 7 Technical specifications 8 Dimension drawings 9 Standards and approvals 10 Hardware description A...

Page 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 3: ...ministrators Service and maintenance personnel Basic knowledge required A solid background in electrical installation personal computers Microsoft operating systems and network technology is required to understand this manual General knowledge in the field automation control engineering is recommended Scope of the operating instructions These operating instructions are valid for all order versions...

Page 4: ...hat may be implemented please visit http www siemens de industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used Use of product versions that are no longer supported and failure to apply the latest updates may incr...

Page 5: ...es on mounting 30 2 4 Notes on ambient and environmental conditions 30 2 5 Information on I O devices 33 2 6 Notes on device and system extensions 34 3 Installing and connecting the device 35 3 1 Preparing for installation 35 3 1 1 Scope of delivery 35 3 1 2 Checking the delivery package 37 3 1 3 Identification data of the device 38 3 2 Installing the device 39 3 2 1 Installation guidelines 39 3 2...

Page 6: ...n options for drives 60 5 3 3 Configure the onboard RAID system 60 5 3 4 Monitoring the onboard RAID system with Intel Rapid Storage Technology 62 5 3 5 Integrating a new drive into the onboard RAID system 63 5 3 6 Data synchronization in the RAID system 64 5 4 Monitoring of the device 65 5 4 1 Monitoring functions 65 5 4 2 SIMATIC IPC DiagBase 66 5 4 3 SIMATIC IPC DiagMonitor 66 5 5 Remote mainte...

Page 7: ...drivers 107 7 4 1 Installing the operating system 107 7 4 2 Installing software and drivers 107 7 5 Configuring firmware BIOS 107 7 6 Backing up data and changing partitions 107 7 7 Recycling and disposal 108 8 Technical specifications 109 8 1 Applicability of technical specifications 109 8 2 General technical specifications 109 8 3 Current power requirements and power supply 111 8 3 1 Current and...

Page 8: ...he motherboard 136 A 2 Internal interfaces 137 A 2 1 Pin assignment of the internal interfaces 137 A 2 2 Device fan supply X512 137 A 2 3 Supply for the power supply fan X515 138 A 2 4 Supply for the serial ATA drives X516 X521 138 A 3 Bus board 139 A 3 1 Expansion card slots on the bus board 139 A 3 2 Pin assignment 12 V power supply connection for expansion cards 141 A 4 External interfaces 142 ...

Page 9: ...Instructions 12 2018 A5E44297201 AA 9 C Markings and symbols 155 C 1 Overview 155 C 2 Safety 155 C 3 Operator controls 155 C 4 Certificates approvals and markings 156 C 5 Interfaces 157 D List of abbreviations 159 D 1 Abbreviations 159 Index 161 ...

Page 10: ...Table of contents SIMATIC IPC627E 10 Operating Instructions 12 2018 A5E44297201 AA ...

Page 11: ...y Connecting I O devices Switching the device on Supplied in printed form with the device Supplied data storage medium Current product infor mation Current notes on the device Changes compared with these operating instructions Online at SIMATIC IPC Documentation http www siemens com simatic ipc doku portal Firmware BIOS de scription Information on Important firmware settings Firmware settings in t...

Page 12: ...i tional extended functions Online at SIMATIC IPC DiagMonitor https support industry siemens com cs ww en view 39129913 SIMATIC IPC Remote Manager Information on Remote maintenance of SIMATIC industrial PCs IPCs via a management PC Using Intel Active Management Technology Intel AMT Online at SIMATIC IPC Remote Manager http support automation siemens com WW view en 48707158 SIMATIC IPC Image Partit...

Page 13: ...ered the features and illustrations described in this manual may differ from the features of your device Maximum industrial compatibility for 24 hour continuous use in industrial environments Maximum processor power in full configuration without loss of power throttling at up to 55 C ambient temperature Full metal enclosure with high electromagnetic compatibility EMC for use in industry Independen...

Page 14: ...ftware optional and signaling software OPC SNMP LAN Remote control and remote maintenance of the device through iAMT Intel Active Management Technology SSD as 2 5 SATA or M 2 NVMe Preventative data backup with the SIMATIC IPC Image Partition Creator High investment protection Platform with embedded Intel components for long term stability Availability 3 to 6 years Assured spare parts availability ...

Page 15: ...nt and control cabinet engineering Process and visualization applications Industrial image processing Quality assurance and monitoring tasks Measurement control and rule based tasks Data acquisition and management The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses In addition to the industrial applications there...

Page 16: ...eset to S0 State Always On This means the device is switched on with the on off switch You then do not need to press the on off button 4 status LEDs Status display of the operating state Page 21 COM1 X30 Serial interface DVI VGA X70 DVI D connection for CRT or LCD monitor with DVI port DisplayPort X71 X72 DisplayPort connection for digital monitor 3 Ethernet X1P1 X2P1 X3P1 X1P1 left RJ45 Ethernet ...

Page 17: ...2 0 1 1 100 240 V AC Power supply connection On off switch You switch on the device with the on off switch This requires that the BIOS setup entry State After G3 is set to S0 State Always On The on off switch does not isolate the device from the power supply Position ON when the symbol is pressed inward on the device Position OFF is the delivery state PCI PCIe expansion cards USB on expansion card...

Page 18: ...he on off switch You then do not need to press the on off button 4 status LEDs Status display of the operating state Page 21 COM1 X30 Serial interface DVI VGA X70 DVI D connection for CRT or LCD monitor with DVI port DisplayPort X71 X72 DisplayPort connection for digital monitor 3 Ethernet X1P1 X2P1 X3P1 X1P1 left RJ45 Ethernet port 1 exclusive PCI interrupt with 10 100 1000 Mbps iAMT capable X2P1...

Page 19: ...S setup entry State After G3 is set to S0 State Always On The on off switch does not isolate the device from the power supply Position ON when the symbol is pressed inward on the device Position OFF is the delivery state PCI PCIe expansion cards USB on expansion card optional 5 slots for expansion cards Slot1 X101 Slot2 X102 Slot3 X103 Slot4 X104 Slot5 X105 Fixing screws for strain relief Device w...

Page 20: ...l design of the device SIMATIC IPC627E 20 Operating Instructions 12 2018 A5E44297201 AA 1 4 2 Rear of the device Removable drives Slots for removable drives RAID status indicators HDD alarm Battery compartment CMOS backup battery Fan ...

Page 21: ...an be controlled by user program Yellow Can be controlled by controller program e g Soft PLC ERROR or L2 Off Red Flashing red Can be controlled by user program or controller program e g Soft PLC MAINT or L3 Off Yellow Red Can be controlled by controller program e g Soft PLC For additional information on controlling the LEDs or the NVRAM with a Windows operating system please refer to the chapter B...

Page 22: ...on with RAID and moni toring software Both off RAID is OK LED lights up red HDD1 is not OK LED lights up red HDD2 is not OK Both light up red RAID is not OK For information on locating the hard disk see section Displaying a defective hard disk of a RAID system in the RAID software Both flash RAID is synchronized Status display of Ethernet ports Status display Status Meaning of the status LED 1 Off...

Page 23: ... Operating Instructions 12 2018 A5E44297201 AA 23 1 5 Internal design of the device 100 240 V AC power supply Slots for removable drives Expansion card slots Heat sink of the processor Expansion card slots Motherboard Slots for memory modules Retainer for expansion cards ...

Page 24: ...net go to Industry Mall https mall industry siemens com 2 Log in with your customer data 3 Select your user language 4 Go to your device in the product catalog tree structure on left Automation technology PC based Automation Industrial PCs Box PC 5 In the tree structure on the left click on SIMATIC IPC627E 6 Select the Accessories tab in the display area SIEMENS spare parts services Information on...

Page 25: ... IPCs to communicate with other systems to alarm worldwide and to create proprietary monitoring applications SIMATIC IPC Remote Manager The SIMATIC IPC Remote Manager enables the use of Intel Active Management Technology Intel AMT By using remote access to SIMATIC IPCs system or program errors can be corrected from a control room without on site presence for example and program updates and firmwar...

Page 26: ...Product description 1 6 Accessories and spare parts SIMATIC IPC627E 26 Operating Instructions 12 2018 A5E44297201 AA ...

Page 27: ... electric shock WARNING Risk of electric shock The on off button and on off switch do not fully disconnect the device from the supply voltage There is also a risk of fire if the device or connecting lines are damaged Always fully disconnect the device from the supply voltage before performing work on the device or when the device will not be used over an extended period of time For control cabinet...

Page 28: ...s in case of non validated plant operation The device is tested and certified on the basis of the technical standards In rare cases functional restrictions can occur during plant operation Validate the correct functioning of the plant to avoid functional restrictions Use in industrial environments Note Use in an industrial environment without additional protective measures This device was designed...

Page 29: ... device A damaged device can be under hazardous voltage and trigger a fire in the machine or plant A damaged device has unpredictable properties and states Death or serious injury could occur Avoid installing and commissioning a damaged device Label the damaged device and keep it locked away Send off the device for immediate repair Damage from condensation NOTICE Damage from condensation If the de...

Page 30: ... can cause death or serious bodily injury Always disconnect the cabinet from the mains before opening it Ensure that the power to the control cabinet cannot be turned on accidentally 2 4 Notes on ambient and environmental conditions Certifications and approvals WARNING Voided approvals If the following conditions for system installation are not observed approvals in accordance with UL 61010 2 201 ...

Page 31: ...lean air is ensured Clean the enclosure surface with a damp cloth and make sure that no water enters the device When you plan your project you should make allowances for The climatic and mechanical environmental conditions specified in the operating instructions Do not operate the device in severe operating conditions which are subject to caustic vapors or gases For installation in a cabinet obser...

Page 32: ...the technical specifications High frequency radiation outside the specified interference immunity ranges can result in device malfunctions Persons are injured and the plant is damaged Avoid high frequency radiation Remove radiation sources from the environment of the device Switch off radiating devices Reduce the radio output of radiating devices Read the information on electromagnetic compatibili...

Page 33: ... capable may only be connected after the device has been disconnected from the power supply NOTICE Damage through regenerative feedback Regenerative feedback of voltage to ground by a connected or installed component can damage the device Connected or built in I Os for example a USB drive are not permitted to supply any voltage to the device Regenerative feedback is generally not permitted Note Wh...

Page 34: ...Always disconnect the power plug before you open the device Only install device or system expansions designed for this device Observe the information on Electromagnetic compatibility provided in the technical specifications Contact your technical support team or the point of sale to find out which device and system expansions are suitable for installation NOTICE Open Equipment IEC EN UL61010 The d...

Page 35: ...r ordered Microsoft Windows operating system Device drivers for installation in operating systems SIMATIC IPC627E Quick Install Guide SIMATIC IPC627E operating instructions Product information Firmware BIOS description Operating instructions for your ordered Microsoft Windows operating system on this device Operating system Depending on the ordered device configuration the device is equipped with ...

Page 36: ...onitoring software SIMATIC IPC DiagBase only with installed Microsoft Windows operating system You will find the latest information on additional software for your device under Accessories and spare parts Page 24 Printed documents SIMATIC IPC627E Quick Install Guide Product Information Important notes on your device SIMATIC IPC PG Quality Control Report ...

Page 37: ...t at the time of delivery lodge a complaint at the shipping company in charge Have the shipper confirm the transport damage immediately 2 Unpack the device at its installation location 3 Keep the original packaging in case you have to transport the unit again 4 Check the Scope of delivery Page 35 and any accessories you may have ordered for completeness and damage Please inform the delivery servic...

Page 38: ...rs or loss The following illustrations are examples The data of your device may differ from the data in these examples Nameplate The following image shows the nameplate on the SIMATIC IPC627E as an example COA label The COA label Certificate of Authenticity is located on the rear of the device Note The COA label is only available on devices shipped with an installed Microsoft Windows operating sys...

Page 39: ...allation and assembly notes under Notes on mounting Page 30 Notes on ambient and environmental conditions Page 30 Securing the device NOTICE Insufficient load carrying capacity If the wall it is mounted on does not have a sufficient load bearing capacity the device may fall and be damaged Ensure that the mounting surface on the wall can bear four times the total weight of the device including fixi...

Page 40: ...mples Material Hole diameter Fixation Concrete 8 mm diameter 60 mm depth Dowel 8 mm diameter 50 mm long Screws 4 5 6 x 50 mm Plasterboard at least 13 mm thick 14 mm diameter Tilting dowel 4 mm diameter at least 50 mm long Metal at least 2 mm thick 5 mm diameter Metal screws 4 mm diameter at least 15 mm long See also Ambient conditions Page 116 Mounting positions Page 41 ...

Page 41: ...f the device in a housing in accordance with IEC EN UL 61010 2 201 is therefore a mandatory requirement for approval or operation An inclination of 20 is permitted for all approved mounting positions Position 1 preferred for wall mounting The interfac es are at the right Position 2 for wall mounting The interfaces are at the left Position 3 desktop An inclination of 15 is allowed in this mounting ...

Page 42: ...uded wall mounting rails allow for space saving installation of the device Note See the notes under Mounting positions Page 41 Mounting of the mounting rails on the device 1 Remove the equipotential bonding screw from the device and attach it to the wall mounting rails 2 Secure the wall mounting rails to the device using the following number of screws SIMATIC IPC627E Six M4 screws torque 3 Nm ...

Page 43: ... the notes under Mounting positions Page 41 Securing the vertical mounting plate to the device 1 Remove the equipotential bonding screw from the device and attach it to the vertical mounting plate 2 Secure the vertical mounting plate to the device using the following number of screws SIMATIC IPC627E Four or 7 M4 screws torque 3 Nm Remove the screw and the toothed lock washer and fasten them again ...

Page 44: ...ertical mounting kit for PC port access from the front The optional vertical mounting kit allows space saving installation of the device Note See the notes under Mounting positions Page 41 Securing the vertical mounting plate to the device Secure the vertical mounting plate on the device using five M4 screws Two screws at the top and two at the bottom of the device ...

Page 45: ...t and ambient temperature of the device and meet the requirements of the following standards ANSI UL 498 and CSA C22 2 No 42 CSA C22 2 No 182 1 CSA C22 2 No 182 2 CSA C22 2 No 182 3 For countries other than the USA and Canada Supply voltage 230 V AC This device is supplied with a safety tested power cord and may only be connected to a grounded SCHUKO socket outlet If you do not use the power cord ...

Page 46: ...ver a large area and is marked with the following symbol Requirements For the equipotential bonding connection you need One TORX T20 screwdriver One equipotential bonding cable with minimum cross section of 2 5 mm2 Procedure 1 Connect the identified equipotential bonding connection thread M4 of the device with the equipotential bonding cable Make sure that the equipotential bonding cable is in con...

Page 47: ... regulations Otherwise there is a risk of fire and electric shock This can result in personal injury or property damage Ensure that the AC or DC connecting cables comply with the safety regulations of the country in which the device is installed and bear the marks required in each case Connect the protective conductor in accordance with the operating instructions WARNING Risk of electric shock The...

Page 48: ...tion under Country specific information on supply voltage Page 45 Screwdriver T10 Procedure 1 Make sure that the ON OFF switch is in position Off to avoid unintentional startup of the device when you plug in the power cord 2 Connect the appliance connector to the device 3 If necessary install the enclosed cable grip 4 Connect the power cable with the safety power outlet ...

Page 49: ...fully disconnect the device from the supply voltage before performing work on the device or when the device will not be used over an extended period of time For control cabinet mounting Use a central easily accessible AC circuit breaker close to the device if possible When you install the device make sure that the power supply connector is easily accessible Note Safety extra low voltage SELV The d...

Page 50: ...y 3 Connect the 24 V DC plug connector to the device Observe the correct polarity of the contacts Protective conductor ground 24 V DC 4 If necessary install the enclosed cable grip 5 Secure the 24 V DC cable to the cable grip using a cable tie Note Reverse polarity protection The 24 V DC power supply is protected against polarity reversal When you confuse the 24 V DC connecting cables and ground t...

Page 51: ...al injury and damage to the machine or plant You should observe the warnings relating to the connection of I O devices in Information on I O devices Page 33 Procedure Note Use the original connections of the I O to be connected without adapters or extensions 1 Connect the I O devices to the respective interfaces Information on the position of the interfaces is available in Front panel Page 16 2 Se...

Page 52: ...ssignment is performed by means of the Control Panel in Windows The IPC is factory set for multi monitoring If needed you can configure the multi monitoring function and the output of the boot screen in the firmware settings see Multi monitoring Page 59 The following table shows the various connection options for the monitors on the device interfaces Motherboard DPP1 DPP2 DVI D Monitor 1 DP X DVI ...

Page 53: ...nned system environments or networks Ethernet You can use the integrated Ethernet interfaces 10 100 1000 Mbps for communication and data exchange with automation devices e g SIMATIC S7 You need the SOFTNET S7 software package for this PROFINET PROFINET can be operated via Standard Ethernet interfaces RT Additional information You can find additional information on the Internet at Technical Support...

Page 54: ...evice You need two cable ties to use the strain relief In addition to the Ethernet cables you can also use this strain relief to protect the four USB cables from inadvertent removal To secure the Ethernet strain relief you will need a TORX T10 screwdriver Procedure 1 Secure the Ethernet USB strain relief with two oval head screws M3 to the device housing 2 Connect the network and USB cables with t...

Page 55: ...the documentation on the supplied data storage medium See also Important instructions and manuals for operating the device Page 11 for more on this 4 2 Configuring automatic switch on of device In the firmware settings you can specify that the device automatically starts up again after a separation from the mains voltage of at least 20 ms as soon as the mains voltage is available again Configure t...

Page 56: ...from the line voltage WARNING Risk of electric shock The on off button and on off switch do not fully disconnect the device from the supply voltage There is also a risk of fire if the device or connecting lines are damaged Always fully disconnect the device from the supply voltage before performing work on the device or when the device will not be used over an extended period of time For control c...

Page 57: ...does no longer respond to keyboard or mouse input Any running operating system will not shut down safely NOTICE Data loss If a hardware reset is performed the device undergoes a hard reboot Data in the main memory is deleted Data on the hard disk drive may be lost The device may be damaged Perform a hardware reset only in the case of an emergency See also General safety instructions Page 27 ...

Page 58: ...Commissioning the device 4 3 Switching off the device SIMATIC IPC627E 58 Operating Instructions 12 2018 A5E44297201 AA ...

Page 59: ...You can find information on this in the detailed firmware BIOS description see Important instructions and manuals for operating the device Page 11 5 2 Drive configurations 5 2 1 RAID1 system The RAID1 system works on the principle of data mirroring on two drives In the event of a defective drive the RAID1 system can continue to work on the remaining drive and thus achieves a high level of availabi...

Page 60: ... The two hard drives required for a RAID1 system can be installed in SIMATIC IPC627E in the following locations For onboard RAID system Drives Page 79 5 3 3 Configure the onboard RAID system If you have ordered a device with an onboard RAID system the RAID system is already configured on delivery If you subsequently set up an onboard RAID system you will still have to configure it Requirements The...

Page 61: ...ion window A list of the available drives is displayed 8 Under Select Disks select the drives that you want to integrate into your RAID system and confirm your selection The mounted drive is provided with a check mark in the list You will find the assignment of the drive to the installation location in the drive cage after the drive name see 9 Select Create Volume The following screen shows the de...

Page 62: ...l Rapid Storage Technology onboard RAID system 1 Select Start Programs Start Intel Display status of the onboard RAID system faulty drive 1 Select the Status tab In the Storage System View area on the right side of the window you will find information on a defective drive a functioning drive Example display status of a RAID1 system Creating a report on the onboard RAID system 1 Select the Help tab...

Page 63: ...or a drive that has been set up as a replacement drive You can find notes on setting replacement drives in the controller documentation 1 Select Start Intel Intel Rapid Storage Technology 2 Select the Preferences menu 3 In the area Automatic Rebuild enable the option Auto rebuild on hot plug Configuring Manual mounting of a new drive before replacing a defective drive The RAID system is configured...

Page 64: ...synchronization in the RAID system NOTICE Danger of incorrect operations on machine and plant delayed system reaction during data synchronization Data is synchronized if a drive fails The system can respond with a delay depending on the size of the drive and system load In extreme cases the execution of keyboard mouse or touch screen commands may be briefly delayed The result may be faulty operati...

Page 65: ...dog Monitoring of the system status and message to determine if a station is still operational If the watchdog is not addressed within a configured monitoring time a watchdog alarm is output A change to the monitoring time is effective immedi ately Depending on the setting the following actions are triggered Reset on Hardware reset is per formed Reset off No action is performed The device is resta...

Page 66: ... device Page 11 5 4 3 SIMATIC IPC DiagMonitor The SIMATIC IPC DiagMonitor monitoring software can be ordered optionally If a device is ordered with SIMATIC IPC DiagMonitor the software is included with the device in the delivery state Information on the software and documentation of SIMATIC IPC DiagMonitor can be found under SIMATIC IPC DiagMonitor https support industry siemens com cs ww en view ...

Page 67: ... grated in the firmware This allows you to restart the IPC and change firmware BIOS settings remotely Remote Power Management SIMATIC IPCs can be turned on and off and restarted from another PC IDE redirection An ISO file on the Help Desk PC can be integrated and used on the SIMATIC IPC as a DVD drive An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 form...

Page 68: ... your device can be ordered as an option You can find information on the software and documentation of SIMATIC IPC Remote Manager under SIMATIC IPC Remote Manager http support automation siemens com WW view en 48707158 Important instructions and manuals for operating the device Page 11 See also SIMATIC IPC software http www automation siemens com mcms pc based automation en industrial pc expansion...

Page 69: ...emory NVRAM optional For applications to store data following a power failure motherboards feature battery buffered NVRAM If the supply voltage fails for more than 20 ms for the AC power supply or more than 5 ms for the DC power supply then you will be informed about this situation by the NAU signal At least 10 ms is available to copy the data to the buffered RAM During this time 128 KB can be sav...

Page 70: ...Operating the device 5 8 Operation without monitor and keyboard SIMATIC IPC627E 70 Operating Instructions 12 2018 A5E44297201 AA ...

Page 71: ...e information in Notes on device and system extensions Page 34 WARNING Malfunctions and electric shock Improper intervention in the device endangers operational reliability and may damage the device The results can be personal injuries and damage to the plant Take the following precautions Always disconnect the power plug before you open the device Close the device after every intervention NOTICE ...

Page 72: ...1 Opening the Device SIMATIC IPC627E 72 Operating Instructions 12 2018 A5E44297201 AA Requirement All connecting cables are unplugged Screwdriver of type Torx T10 Procedure 1 Remove the four marked screws in the cover 2 Remove the cover by lifting it up ...

Page 73: ...3 Expansion cards with 3 3 V and 5 V supply voltage can be used PCIe Gen 1 Gen 2 Gen 3 Conditions of use of expansion cards The expansion cards must not exceed the specified dimensions If the height is exceeded you may experience contact problems malfunctions and difficulties with the assembly You can find the permitted dimensions for expansion cards under Dimension drawing of the expansion cards ...

Page 74: ... 129 If the permissible height is exceeded contact problems malfunctions and installation difficulties cannot be ruled out Requirements The device is open see Opening the Device Page 71 Procedure Installation NOTICE Damage to the expansion card The expansion card can break if excessive force is used Do not apply any pressure Do not apply excessive force on the slider when you push it onto the expa...

Page 75: ...elevant slot 3 Secure the expansion card with the card retainer 4 Fasten the slot cover of the expansion card see 1 Notes on the allocation of resources The slots for the expansion cards come with exclusive interrupts The assignment of the PCI IRQ line to the PCI slot is explained in the chapter Bus board Page 139 Procedure Removal Proceed in reverse order of installation ...

Page 76: ... Slot X200 DIMM2 2 Combination 1 4 GB 8 GB 16 GB 16 GB Combination 2 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 32 GB Combination 3 Combinations of three memory modules are not permitted Combination 4 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 64 GB Usable memory modules DIMM DDR4 memory modules Memory transaction rate 2666 MT sec unbuffered without ECC Conditions of use of memory module...

Page 77: ...e Device Page 71 Installing a memory module Note Equipment of the memory modules Make sure that the memory modules are equipped in the following order 1 memory module Slot at the very end 2 1 2 memory modules Slot at the very end 2 1 and the third from the end 1 1 3 memory modules not allowed 4 memory modules all slots 2 1 2 2 1 1 1 2 1 Note where the cutout reverse polarity protection is located ...

Page 78: ...ribed above when removing the memory modules 1 Loosen the locking mechanisms on the left and right of the slot 2 Remove the memory module from the slot 3 Close the device Display of a changed memory configuration A new memory module is automatically detected When switching on the device and starting the BIOS Setup using F2 the current memory size is displayed under Total Memory See also General sa...

Page 79: ...drive and destroy data Only remove the removable tray from the device when the drive is inactive Observe the ESD guidelines Requirement An original spare part that is a drive approved for this device see notes in Accessories Hardware Page 24 If there is no RAID system The device is fully disconnected from the line voltage see Switching off the device Page 56 The device you wish to replace is inact...

Page 80: ...ntacts of the drive when you do this 5 Fasten the new drive with the screws to the base of the removable tray Only use the original screws 6 Fold the tray bracket out of the removable tray as far as it will go and slide the removable tray fully into the drive cage Ensure that the removable tray fits tightly in the drive cage 7 Close the tray bracket 8 Lock the removable tray with the key Note The ...

Page 81: ...e is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is an SSD of the same type see information under Accessories Hardware Page 24 Procedure Removal 1 Remove the marked screws 2 Remove the marked screws and place the SSD on its side ...

Page 82: ... to the device 6 4 Drives SIMATIC IPC627E 82 Operating Instructions 12 2018 A5E44297201 AA 3 Remove the marked connectors 4 Remove the marked screws 5 Remove the carrier with the connectors remove the marked screws and take out the SSD ...

Page 83: ... to the device 6 4 Drives SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 83 Procedure Installation Proceed in reverse order When connecting multiple drives observe the assignments of the port connections see PCB labeling ...

Page 84: ... from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a hard disk drive of the same type see information under Accessories Hardware Page 24 Procedure Removal 1 Remove the marked screws and place the hard disk drive on its side 2 Remove the marked screws and the drive ca...

Page 85: ... assigning parameters to the device 6 4 Drives SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 85 3 Remove the marked connectors and remove the hard disk Procedure Installation Proceed in reverse order ...

Page 86: ...an be performed without shutting down the device The new hard disk can be integrated into the RAID system at operating system level with the RAID software Synchronization may take several hours depending on system load Replacing a defective drive in the RAID system 1 Determine which drive was reported by the RAID software as defective 2 Replace the appropriate drive see Drives Page 79 3 Replace th...

Page 87: ...NVMe SSDs with an length of up to 110 mm Phillips screwdriver P1 The drive bay module and the power supply are removed see Replacing the bus board Page 100 Procedure 1 Place the bus board on a suitable surface so that it lies flat and plane 2 Remove the marked screw 3 Lift the M 2 NVMe SSD slightly as shown and pull it out of the direct connector socket 4 Lay the thermal pad on the bus board in su...

Page 88: ...ting Instructions 12 2018 A5E44297201 AA 5 Insert the M 2 NVMe SSD slightly inclined from above into the provided direct connector socket 6 Carefully push the M 2 NVMe SSD down and secure it with the screw 7 Install the bus board and then the drive bay module and the power supply again ...

Page 89: ...intenance intervals To maintain high system availability we recommend the preventative replacement of those PC components that are subject to wear The table below indicates the intervals for this replacement Component Replacement interval Hard disk drive 3 years Fan 3 years CMOS backup battery 5 years SSD Depends on the type of use 1 1 The interval for replacement of the flash drives SSD depends g...

Page 90: ...ent The device is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a fan of the same type see information under Accessories Hardware Page 24 Procedure Removal 1 Remove the two screws and remove the air guide pulling it up vertically 2 Loosen the plastic...

Page 91: ...aintenance and repair 7 3 Removing and installing hardware SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 91 3 Remove the four plastic rivets on the enclosure 4 Take the fan out of the enclosure ...

Page 92: ...lation Proceed in reverse order of removal Note Install only a fan of the same type Note the correct mounting position of the fan Direction of flow Make sure that the blades bars of the fan housing are on the outside of the enclosure Run the power supply cable along the enclosure edge and fasten the cable The marked symbols show the rotation and flow direction of the fan ...

Page 93: ...ltage supply and all connecting cables have been unplugged The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a fan of the same type see information under Accessories Hardware Page 24 Procedure Removal 1 Remove the four plastic rivets on the enclosure and remove the marked screw 2 Pull the power supply connector and remove th...

Page 94: ...nance and repair 7 3 Removing and installing hardware SIMATIC IPC627E 94 Operating Instructions 12 2018 A5E44297201 AA 3 Take the power supply out of the enclosure 4 Remove the power supply fan and pull the fan plug ...

Page 95: ...ed in reverse order of removal Note Install only a fan of the same type Note the correct mounting position of the fan Direction of flow Make sure that the blades bars of the fan housing are on the outside of the enclosure Run the power supply cable along the enclosure edge and fasten the cable The marked symbols show the rotation and flow direction of the fan ...

Page 96: ...recommended approved by SIEMENS Do not throw lithium batteries into fire do not solder on the cell body do not recharge do not open do not short circuit do not reverse polarity do not heat above 100 C and protect from direct sunlight moisture and condensation Requirements An original spare part that is a backup battery of the same type article number of lithium battery A5E00047601 CR2450 N You hav...

Page 97: ...ng hardware SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 97 Procedure 1 Remove the marked screw 2 Remove the battery holder 3 Replace the battery reinsert the battery holder and fasten it with the screw See also Accessories Hardware Page 24 ...

Page 98: ...ce is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part i e a power supply of the same type see notes under Accessories Hardware Page 24 Procedure Removal 1 Remove the marked screw 2 Pull the power supply connector and remove the marked screws ...

Page 99: ...moving and installing hardware SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 99 3 Take the power supply out of the enclosure Procedure Installation Note Install only a power supply of the same type Proceed in reverse order ...

Page 100: ...he device is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 Procedure Removal 1 Remove all modules from the slots 2 Remove the marked screws on the bus board 3 Remove the marked screws 4 Remove the back up battery holder see Changing the backup battery Page 96 ...

Page 101: ...maintenance and repair 7 3 Removing and installing hardware SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 101 5 Remove the marked screws and remove the top drive bay module including hard disk ...

Page 102: ...enance and repair 7 3 Removing and installing hardware SIMATIC IPC627E 102 Operating Instructions 12 2018 A5E44297201 AA 6 Remove the marked hexagonal pins and remove the bottom drive bay module including hard disk ...

Page 103: ...C627E Operating Instructions 12 2018 A5E44297201 AA 103 7 Remove the power supply see also Replace power supply Page 98 8 Pull the bus board from the motherboard as shown in the figure Procedure Installation Note Install only a bus board of the same type Proceed in reverse order ...

Page 104: ...pening the Device Page 71 The memory modules have been removed The air guide has been removed see chapter Replacing device fans Page 90 An original spare part i e a processor of the same type Only an approved processor is permitted to be installed on the motherboard NOTICE Damage to the processor If the installed processor is operated with a higher clock frequency than permitted it can be destroye...

Page 105: ...the marked rails on the side Do not touch the processor and its connections in the process see ESD guidelines under General safety instructions Page 27 Note The contact springs of the socket are highly sensitive to mechanical damage e g caused by an incorrectly inserted CPU or foreign objects and their entire surface may only touch the contact side of the processor flat 4 Install the new processor...

Page 106: ...nd lock it again NOTICE Damage to the processor due to excessive force The locking mechanism may be stuck The locking mechanism is damaged while being pressed down The processor is not correctly locked in place by the bay The result may be malfunctions Do not use excessive force Tilt the lever back again and try again See also Contacts http www siemens com automation partner SIMATIC IPC after sale...

Page 107: ...e START_DoucAndDrivers CMD 3 Install the desired software and drivers 7 5 Configuring firmware BIOS You can find information on configuring firmware BIOS and on the firmware settings in the delivery state in the Firmware BIOS description https support industry siemens com cs ww en view 109760621 Note If your IPC fails to boot for example by crashing during a BIOS update contact your local SIEMENS ...

Page 108: ...ling and disposal The devices described in these operating instructions can be recycled thanks to their low level of pollutants Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device and dispose of it according to the relevant regulations in your country ...

Page 109: ...nta tion Dimensions Device with two expansion slots 295 265 93 W H D in mm Device with five expansion slots 295 x 265 x 155 W H D in mm Weight Device with two expansion slots approx 5 kg Device with five expansion slots approx 7 kg Supply voltage AC Nominal 100 240 V AC 15 10 wide range Supply voltage DC 1 Nominal 24 V DC 20 20 SELV 1 Input current AC Continuous current up to 1 7 A up to 50 A for ...

Page 110: ...overvoltages Device is designed for connection to supply with overvoltage category II transient overvoltages up to 2500 V Safety specifications IEC 61010 2 201 EN 61010 2 201 UL 61010 2 201 CSA C22 2 No 61010 2 201 1 The device must only be connected to a 24 V DC power supply which meets the require ments of safe extra low voltage SELV according to IEC EN DIN EN UL 601010 2 201 A protective conduc...

Page 111: ...urrent and 4 USB3 1 low current 4 The total power for individual PCI PCIe slots cannot exceed 25 W The total power for USB and PCI PCIe slots cannot exceed 30 W 5 The total power of the 5 V and 3 3 V voltage must not exceed 60 W Table 8 2 IPC627E five expansion slots Component Voltage 3 3 V 5 V 12 V 12 V Base device 1 2 1 53 A 4 1 A 5 45 A 1 x 2 5 SATA SSD 2 0 8 A 1 x 2 5 SATA HDD 2 0 6 A M 2 NVMe...

Page 112: ...5 SATA SSD 0 02 A 0 17 A 7 W 1 M 2 NVMe SSD 0 04 A 0 33 A 7 W 1 2 5 SATA HDD 0 02 A 0 13 A 3 W USB ports Max 0 06 A Max 0 54 A Max 13 W PCI PCIe slots 0 16 A max 1 54 A max Max 37 W Table 8 4 IPC627 five expansion slots Component Current consump tion 230 V AC Current consump tion 24 V DC Power consumption efficiency 0 85 Base device 0 3 A 3 0 A 70 W 1 2 5 SATA SSD 0 02 A 0 17 A 7 W 1 M 2 NVMe SSD ...

Page 113: ...ge in the normal and buffered mode when used with SIMATIC PCs with an active PFC UPS characteristics are described and classified in the standards EN 50091 3 and IEC 62040 3 Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification VFI SS or VI SS Power supply characteristics AC power supply Input data Voltage Nominal 100 240 V AC 15 10 wide rang...

Page 114: ...ations DC power supply DC Degree of protection IP 20 in installed state Protection class VDE 0106 Power supply characteristics DC power supply Input data Voltage Nominal 24 V DC 20 20 SELV isolated Continuous current Max 8 A Starting current load independent up to 13 A for 50 ms Active power 176 W Output data Voltages 12 V 12 5 A Secondary power output Max 150 W ...

Page 115: ...V according to IEC 61000 4 5 symmetrical surge 2 kV according to IEC 61000 4 5 asymmetrical surge Noise immunity on signal lines 1 kV to IEC 61000 4 4 Burst Length 3 m 2 kV in accordance with IEC 61000 4 4 Burst length 3 m 2 kV in accordance with IEC 61000 4 5 Surge length 30 m Immunity to electrostatic dis charge 6 kV contact discharge in accordance with IEC 61000 4 2 8 kV air discharge in accord...

Page 116: ...o condensation Air pressure Operation 1080 to 795 hPa corresponds to an altitude of 1000 to 2000 m Storage transport 1080 to 660 hPa corresponds to an altitude of 1000 to 3500 m Mechanical ambient conditions Vibration Operation 1 Storage transport tested to DIN IEC 60068 2 6 10 to 58 Hz 0 0375 mm 58 Hz to 500 Hz 1 m s2 5 to 9 Hz 3 5 mm 9 to 500 Hz 9 8 m s2 Shock resistance Operation Storage transp...

Page 117: ...voltages may not exceed 25 W Expansion card slots Expansion card slots IPC627E with two expansion slots bus module 2 x PCI Slot 1 PCI Specification Rev 2 3 length Max 185 mm Slot 2 PCI Specification Rev 2 3 length Max 185 mm Expansion card slots IPC627E with two expansion slots bus module 1 x PCI and 1 x PCIexpress x16 Slot 1 PCI Specification Rev 2 3 length Max 185 mm Slot 2 PCIexpress x16 Specif...

Page 118: ...with adapter also VGA monitor Keyboard USB support Mouse USB support USB 4 USB 3 1 type A high current backward compatible 2 USB 3 1 type C high current backward compatible Ethernet 1 3 Ethernet interface RJ45 10 100 1000 Mbps 1 x Ethernet 1 Intel Jacksonville i219 LM AMT capable 4 2 x Ethernet 2 3 Intel Springville i210 AT Wake on LAN Remote Boot and the following Teaming modes are supported Adap...

Page 119: ...guage user interface MUI 5 languages English German French Spanish Italian You can find information on ordered Microsoft Windows operating systems under Important instructions and manuals for operating the device Page 11 Boot mode and partitions in the delivery state Delivery state for Windows 10 Windows 10 boots in UEFI mode in the delivery state The following table lists the partitioning for dis...

Page 120: ...Technical specifications 8 10 Technical specifications of the operating systems SIMATIC IPC627E 120 Operating Instructions 12 2018 A5E44297201 AA ...

Page 121: ...27E Operating Instructions 12 2018 A5E44297201 AA 121 Dimension drawings 9 9 1 Dimension drawings of SIMATIC IPC627E 2 expansion slots Dimension drawing for mounting without wall mounting rails All dimensions in mm ...

Page 122: ...drawings 9 1 Dimension drawings of SIMATIC IPC627E 2 expansion slots SIMATIC IPC627E 122 Operating Instructions 12 2018 A5E44297201 AA Dimension drawing for mounting with wall mounting rails All dimensions in mm ...

Page 123: ...rawings 9 1 Dimension drawings of SIMATIC IPC627E 2 expansion slots SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 123 Dimension drawing for mounting with vertical mounting kit All dimensions in mm ...

Page 124: ... drawings of SIMATIC IPC627E 2 expansion slots SIMATIC IPC627E 124 Operating Instructions 12 2018 A5E44297201 AA Dimension drawing for installation with the vertical mounting kit for PC port access from the front All dimensions in mm ...

Page 125: ... of SIMATIC IPC627E 5 expansion slots SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 125 9 2 Dimension drawings of SIMATIC IPC627E 5 expansion slots Dimension drawing for mounting without wall mounting rails All dimensions in mm ...

Page 126: ...drawings 9 2 Dimension drawings of SIMATIC IPC627E 5 expansion slots SIMATIC IPC627E 126 Operating Instructions 12 2018 A5E44297201 AA Dimension drawing for mounting with wall mounting rails All dimensions in mm ...

Page 127: ...rawings 9 2 Dimension drawings of SIMATIC IPC627E 5 expansion slots SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 127 Dimension drawing for mounting with vertical mounting kit All dimensions in mm ...

Page 128: ... drawings of SIMATIC IPC627E 5 expansion slots SIMATIC IPC627E 128 Operating Instructions 12 2018 A5E44297201 AA Dimension drawing for installation with the vertical mounting kit for PC port access from the front All dimensions in mm ...

Page 129: ...9 3 Dimension drawing of the expansion cards SIMATIC IPC627E Operating Instructions 12 2018 A5E44297201 AA 129 9 3 Dimension drawing of the expansion cards Short PCI or PCIe expansion card Long PCI or PCIe expansion card ...

Page 130: ...Dimension drawings 9 3 Dimension drawing of the expansion cards SIMATIC IPC627E 130 Operating Instructions 12 2018 A5E44297201 AA ...

Page 131: ...o interfer ence Industry EN 61000 6 4 EN 61000 6 2 Residential and commercial areas and small busi nesses EN 61000 6 3 EN 61000 6 1 The devices are compliant with EN 61000 3 2 Transient currents and EN 61000 3 3 Voltage fluctuation and Flicker 2014 35 EU Electrical equipment for use within specific voltage limits Low Voltage Directive Conformance with this standard has been verified according to E...

Page 132: ...ction and sales meets the requirements of ISO 9001 This has been certified by DQS the German society for the certification of quality management systems Software license agreements If the device is supplied with preinstalled software you must observe the corresponding license agreements 10 3 UL approval The following approvals are available for the device Underwriters Laboratories UL according to ...

Page 133: ...tial area is likely to cause harmful interference in which case the user will be required to correct the inter ference at his own expense Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations Modifications Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Conditions of ...

Page 134: ...and light industrial environments This product meets the requirements of the standard EN 61000 6 3 Generic standards Emission standard for residential commercial and light industrial environments 10 7 Eurasion Customs Union EAC Identification for Eurasion Customs Union EAC Eurasian Conformity Customs union of Russia Belarus and Kazakhstan Declaration of conformity according to Technical Regulation...

Page 135: ...board consists of these main components Processor and chip set four slots for memory modules internal and external interfaces and the Flash BIOS Slots for memory modules Processor Slots for bus boards Technical features of the motherboard Technical features of the motherboard can be found under Technical specifications of the motherboard Page 117 ...

Page 136: ...t3 X523 3 2xUSB 2 0 X13 11 USB 2 0 X17 IPC677E only 21 SATA 0 Port2 X526 4 COM1 X30 12 LVDS X9 IPC677E only 22 CPU fan X513 5 DVI X70 13 Backlight X4007 IPC677E only 23 BIOS Recovery X594 6 2x DPP X71 X72 14 1x USB 2 0 X562 24 RAM DIMM1 2 X190 7 LAN 1 X1 P1 15 HDD fan X511 IPC627E 5 only 25 RAM DIMM1 1 X19 LAN 2 X2 P1 16 PS fan X52 26 RAM DIMM2 2 X200 LAN 3 X3 P1 17 4x SATA SV X516 X519 27 RAM DIM...

Page 137: ...t included in scope of delivery contact your local SIEMENS representative Serial ATA Internal Serial ATA max 2 4 drives operable Connection for PS serial ATA Internal Voltage supply for serial ATA Connection for PS fan Internal Voltage supply for CPU fan 4 pin male connector Connection for equip ment fan Internal Voltage supply for equipment fan 4 pin male connector Backup battery Internal Voltage...

Page 138: ...3 Supply for the power supply fan X515 Pin Name Meaning 1 GND Ground 2 12 V Switched voltage supply 3 PG1 FAN_CLK Clock signal 4 PWM PWM signal A 2 4 Supply for the serial ATA drives X516 X521 Pin Name Meaning 1 12 V Output power supply 2 GND Ground 3 GND Ground 4 5 V Output power supply 5 3 3 V Output power supply ...

Page 139: ...n cards The bus board is available in the following designs Information on pin assignment is available in the sections below Version 1 IPC627E 2 slots Slot 1 2 PCI 12 V power supply connection see Pin assignment 12 V power supply connection for expan sion cards Page 141 Version 2 IPC627E 2 slots Slot 1 PCI Slot 2 PCI Express x16 12 V power supply connection see Pin assignment 12 V power supply con...

Page 140: ...echanical x16 Slot 1 PCI Express x16 12 V power supply connection see Pin assignment 12 V power supply connection for expan sion cards Page 141 Version 4 IPC627E 5 slots Slot 1 2 3 PCI Slot 4 PCI Express x4 mechanical x16 Slot 5 PCI Express x16 12 V power supply connection see Pin assignment 12 V power supply connection for expan sion cards Page 141 ...

Page 141: ... 3 2 Pin assignment 12 V power supply connection for expansion cards Pin Name Meaning Input Output 1 12 V 1 12 V voltage Output 2 GND Ground 3 GND Ground 4 5 V 1 5 V voltage Output 1 max permitted current 1 A with this power demand the total power demand for the PCI slots are not allowed to be exceeded ...

Page 142: ...erface specifications and the intended use Interface Connector Description Assignment COM1 X30 9 pin D sub connector 12 V USB 3 1 X60 X62 X64 X65 USB 3 1 female connector Type A 5 V 900 mA up to 10 Gbps USB 3 1 type C X61 X63 USB 3 1 female connector Type C 5 V 1 5 A to 3 0 A up to 10 Gbps Ethernet 1 2 and 3 X1P1 X2P1 X3P1 RJ45 up to 1 Gbps DVI D X70 24 pin DVI D female connector 5 V 500 mA DPP X7...

Page 143: ...location The table describes the assignment of the I O addresses in the factory state of the device Static area I O address hex Size bytes Description of the basic function Possible alternative function from to 0000 001F 32 DMA controller 0020 0021 2 Programmable interrupt controller 0022 0023 2 Not used 0024 0025 2 Programmable interrupt controller 0026 0027 2 Not used 0028 0029 2 Programmable in...

Page 144: ...1 Motherboard resources 0081 0091 17 DMA controller 0092 0092 1 Motherboard resources 0093 009F 13 DMA controller 00A0 00A1 2 Programmable interrupt controller 00A2 00A3 2 Not used 00A4 00A5 2 Programmable interrupt controller 00A6 00A7 2 Not used 00A8 00A9 2 Programmable interrupt controller 00AA 00AB 2 Not used 00AC 00AD 2 Programmable interrupt controller 00AE 00AF 2 Not used 00B0 00B1 2 Progra...

Page 145: ...3AF 48 Not used 03B0 03BB 12 Graphics 03BC 03BF 4 Reserved 03C0 03DF 32 Graphics 03E0 03E7 8 Not used 03E8 03EF 8 Reserved Reserved for COM1 or COM2 03F0 03F7 8 Not used 03F8 03FF 8 COM1 Can be deactivated in setup then free Reserved for COM1 or COM2 Dynamic range resources are managed by means of Plug and Play functionality 0400 0453 84 Motherboard resources 04D0 04D1 2 Programmable interrupt con...

Page 146: ...tem A distinction is made between the PIC and APIC modes The table describes the assignment of the interrupts in the delivery state of the device Y Interrupt in APIC mode Z BIOS Default Interrupt in PIC mode e g DOS 1 Host PCI IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode Host PCI IRQ A to H will be automatically assigned IRQ 0 to 15 by BIOS in PIC mode A specific assignment can ...

Page 147: ...t assignment of the slot connectors on the bus board 1 Host PCI IRQ A to H will be assigned IRQ 16 to 23 permanently in ACPI mode Host PCI IRQ A to H will be automati cally assigned IRQ 0 to 15 in PIC mode A specific assignment can not be enforced Y Interrupt in APIC mode Z BIOS Default Interrupt in PIC mode e g DOS ...

Page 148: ...21 1 PCI Express slot 16 1 3 1 Requirement The modules in the PCI slots each require only one interrupt 2 Requirement VGA and PCIexpress do not require an interrupt 3 Requirement VGA does not require an interrupt and Ethernet1 is disabled Assigning exclusive interrupts in the firmware PIC mode The interrupts are automatically assigned to the slots at system startup due to the default settings in s...

Page 149: ...000B FFFF 32 K VGA graphics text refresh memory 000C 0000 000C BFFF 48 K VGA BIOS expansion 000C 0000 000C FFFF 64 K VGA BIOS Always allocated or reserved 000E 0000 000F FFFF 2 64K DMI data System BIOS Op tions ROMs PXE RAID 0010 0000 CFFF FFFF 3 2 GB System memory 4 GB memory configuration Depends on memory configuration EFFF F000 EFFF FFFF 4 K Motherboard resources F000 0000 F3FF FFFF 64 M Mothe...

Page 150: ...Hardware description A 5 System resources SIMATIC IPC627E 150 Operating Instructions 12 2018 A5E44297201 AA ...

Page 151: ...Your local representative http www automation siemens com mcms aspa db en Pages default aspx Training center http sitrain automation siemens com sitrainworld AppLang en Industry Mall https mall industry siemens com When contacting your local representative or Technical Support please have the following information at hand Article number of the device MLFB BIOS version for industrial PC or image ve...

Page 152: ...n set to dark Increase the screen brightness For detailed infor mation refer to the monitor operating instructions The power cord or the monitor cable is not connected Check whether the power cord has been properly connected to the monitor and to the system unit or to the grounded shockproof outlet Check whether the monitor cable has been properly connected to the system unit and to the monitor If...

Page 153: ...Problems when booting the device Problem Cause Remedy After changing the hard disk the system does not boot from the RAID array RAID array does not have highest boot priority Change the boot priority in the firmware BIOS under Boot Boot device Permit RAID system in the boot priority Give RAID system top boot priority After changing the drive un used is indicated for the rele vant SATA port System ...

Page 154: ...s activated Install the software again with the help of the sup plied data storage medium B 2 4 Problems when using expansion cards Problem Cause Remedy The device crashes during startup I O addresses are assigned twice Hardware interrupts and or DMA channels are assigned twice Signal frequencies or signal levels are not adhered to Different pin assignment Check your computer configuration If the ...

Page 155: ...s The symbols on your device may vary in some details from the symbols shown in the following tables C 2 Safety Symbol Meaning Symbol Meaning Warning observe the supplied docu mentation Lock is closed Attention radio equipment Lock is open Disconnect the power plug before opening Opening for Kensington lock Attention ESD Electrostatic sensitive device Warning of hot surface C 3 Operator controls S...

Page 156: ...rmation in the operating instructions for your device Symbol Meaning Symbol Meaning Approved for Australia and New Zea land Marking for the Eurasian Customs Union Approved for China Test mark of Factory Mutual Re search CE markings for European countries Marking of Federal Communications Commission for the USA EFUP Environment Friendly Use Period marking for China Approved for Korea Test mark of t...

Page 157: ...ductor terminal PS 2 keyboard interface Connection for functional earthing equipotential bonding line Multimedia Card Reader DisplayPort interface Smart Card Reader DVI D interface Line In LAN interface not approved for con necting WAN or telephone Line Out Serial port Microphone input USB port Universal Audio Jack USB 2 0 high speed port Headphone output USB 3 0 super speed port USB 3 1 SuperSpee...

Page 158: ...Markings and symbols C 5 Interfaces SIMATIC IPC627E 158 Operating Instructions 12 2018 A5E44297201 AA ...

Page 159: ...xide semiconductors COA Certificate of Authenticity Microsoft Windows Product Key COM Communications Port Term for the serial interface CPU Central Processing Unit CPU CRT Cathode Ray Tube CSA Canadian Standards Association Canadian organization for tests and certifications according to own or binational standards with UL USA standards DC Direct Current DC current DMA Direct Memory Access Direct m...

Page 160: ...pply OPC OLE for Process Control Standardized interface for industrial processes PCI Peripheral Component Interconnect High speed expansion bus PCIe Peripheral Component Interconnect ex press High speed serial differential full duplex PtP interface with high data rate PIC Programmable Interrupt Controller Programmable interrupt controller PXE Preboot Execution Environment Software for running new ...

Page 161: ...ng off 57 Device fan See Fan Device fan supply 137 Dimension drawings Device 121 Dimensional drawings Expansion card 129 Dimensions 109 Drive drive in the removable tray 79 E EAC 134 Equipotential bonding 46 Ethernet 118 Ethernet strain relief 54 EU Declaration of Conformity 131 Expansion Memory 76 Expansion modules Installing 74 F Fan 90 Removal 90 FCC 133 Front panel 20 G Graphics controller 118...

Page 162: ... hardware interrupt 148 Permitted mounting positions 41 Power consumption 109 Power factor correction 113 Power requirements 111 Power supply WinAC module 141 Power supply fan Removal 93 98 Power supply unit 98 Power supply unit Removing 98 Processor 117 Removal 105 PROFIBUS 53 PROFINET 53 R RAID 154 RAID system Automatically integrating a new drive 63 Display of the defective drive 60 Manually in...

Page 163: ... voltage 109 For countries other than the USA and Canada 45 USA and Canada 45 Switching on the device Configure automatic startup 55 System resources 143 I O address allocation 143 T Temperature 116 V Vertical mounting 43 Front interfaces 44 W Wall mounting 42 Weight 109 WinAC module Power supply connection 141 ...

Page 164: ...Index SIMATIC IPC627E 164 Operating Instructions 12 2018 A5E44297201 AA ...