Technical specifications
8.1 General specifications
SIMATIC IPC1047E
104
Operating Instructions, 03/2021, A5E50259546-AA
Safety
Protection class
Protection class I according to IEC 61140
Degree of pollution
Device is designed for environments with pollution degree 2
Transient overvoltages
Device is designed for connection to supply with overvoltage catego-
ry II (transient overvoltages up to 2500 V)
Safety regulations
•
IEC 61010-2-201
•
EN 61010-2-201
•
UL 61010-2-201
•
CSA C22.2 No 61010-2-201
Electromagnetic compatibility (EMC)
Interference emission
EN 61000-6-3, FCC Class A
EN 61000-6-4;
CAN/CSA-CISPR 32, EN 55032 Class B
EN 61000-3-2 class D, EN 61000-3-3
Noise immunity: Conducted
disturbance variables on sup-
ply lines
± 2 kV, according to IEC 61000-4-4, burst
± 2 kV, according to IEC 61000-4-5, surge sym.
± 2 kV, according to IEC 61000-4-5, surge asym.
Noise immunity on signal lines ± 1 kV; according to IEC 61000-4-4; burst; length < 30 m
± 2 kV; according to IEC 61000-4-4; burst; length > 30 m
± 2 kV; according to IEC 61000-4-5; surge; length > 30 m
Immunity to discharge of
static electricity
± 4 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
Immunity to RF interference
•
10 V/m, 80...1000 MHz and 1.4...2 GHz,
80% AM 1 kHz, according to IEC 61000-4-3
•
3 V/m 2...6 GHz, 80% AM 1 kHz,
according to IEC 61000-4-3
•
10 V, 15 KHz...80 MHz, 80% AM 1 kHz,
according to IEC 61000-4-6
Magnetic field
100 A/m, 50 Hz/60 Hz, according to IEC 61000-4-8
Climatic ambient conditions
Temperature
Tested in accordance with IEC 60068-2-2, IEC 60068-2-1,
IEC 60068-2-14
During operation
0 °C … +50° C
1
in basic configuration and with drive cage type B
0 °C … +40 °C if expansion cards are inserted (maximum configura-
tion) or with drive cage type A
For the definitions of basic and maximum configuration, see section
"Configuration variants (Page 57)".
1
Also observe the installation options and temperature specifications
in section "Overview (Page 64)".
Storage/transport
Gradient
–20 °C … +60 °C
≤ 20°K/h, no condensation
Relative humidity
Tested in accordance with IEC 60068-2-78, IEC 60068-2-30