C-1
ET 200S Interface Module IM 151/CPU
A5E00058783-01
Execution Times of the SFCs and SFBs
The CPU component of the IM 151/CPU provides you with different system
functions and system function blocks for program scanning and diagnostics, for
example. You can call these system functions/system function blocks in your user
program using the number of the SFC.
For a detailed description of all system functions/system function blocks, refer to
the reference manual
STEP 7 System and Standard Functions. This includes how
to call the system functions and which parameters you have to enter.
C.1
System Functions (SFCs)
SFC
No.
Name
Description
Execution
Time in
s
0
SET_CLK
Sets the clock time
295
1
READ_CLK
Reads the clock time
193
2
SET_RTM
Sets the operating hours counter
62
3
CTRL_RTM
Starts/stops the operating hours counter
57
4
READ_RTM
Reads the operating hours counter
86
5
GADR_LGC
Reads the free address of the channel
x of the signal module
on module slot
y.
148
6
RD_SINFO
Read the start information of the current OB.
116
+3 per byte
7
DP_PRAL
Triggers a process interrupt from the user program of the
CPU as DP slave through to DP master.
228
14
DPRD_DAT
Reads consistent user data
141
+3 per byte
15
DPWR_DAT
Writes consistent user data
143
17
ALARM_SQ
Creates acknowledgeable, block-specific messages
252
18
ALARM_S
Creates non-acknowledgeable, block-specific messages
248
19
ALARM_SC
Determines the acknowledgment status of the last
ALARM_SQ arrived message
115
20
BLKMOV
Copies variables of any type
Note: You can only use SFC20 for process-related DBs, i.e.
the ”Unlinked” check box in the object properties is not selec-
ted. Otherwise, you will receive the W#16#8092 error code
(=block is not process-related) as the RET_VAL.
84
+1.6 per byte
C
Summary of Contents for SIMATIC IM 151/CPU
Page 6: ...Important Information vi ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 14: ...Contents xiv ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 42: ...ET 200S in the PROFIBUS Network 3 12 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 68: ...Commissioning and Diagnostics 4 26 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 98: ...Technical Specifications 6 8 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 108: ...Cycle and Response Times 7 10 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 190: ...Execution Times of the SFCs and SFBs C 4 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...
Page 196: ...Migration of the IM 151 CPU D 6 ET 200S Interface Module IM 151 CPU A5E00058783 01 ...