Examples/applications
6.7 UDTs of FB 45 / FC 45
FC 45
6-18
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
UDT 260: Result of MDS status (mode 1, RF300)
Table 6-8
UDT 260 "MDS status (mode 1, RF300)"
Address
Name
Type
Comment
0.0
STRUCT
+0.0
status_info
BYTE
MDS status mode
+1.0
UID
ARRAY[1...8]
BYTE
Number of MDS (unique identifier)
+9.0
MDS_type
BYTE
MDS type
01 = Tag without FRAM
02 = Tag with FRAM 8KB
03 = Tag with FRAM 32KB
04 = Tag with FRAM 64KB
+10.0
Lock_state
BYTE
EEPROM write protection status
QRWXVHG
%LW
%ORFN))))
%ORFN))))
%ORFN))))%
%ORFN))&)))
%ORFN))))
:ULWHSURWHFWLRQVWDWXV
EORFNQRWSURWHFWHGUZ
EORFNSURWHFWHGUR
+11.0
to
+16.0
res.
Reserved
=18.0
END_STRUCT
UDT 270: Result of MDS status (mode 2, RF300)
Table 6-9
UDT 270: "MDS status (mode 2, RF300)"
Address
Name
Type
Comment
0.0
STRUCT
+0.0
status_info
BYTE
MDS status mode
+1.0
UID
ARRAY[1...8]
BYTE
Number of MDS (unique identifier)
+9.0
LFD
BYTE
Relationship between power flow density
limit and actual measured value
+10.0
FZP
BYTE
Error counter, passive (errors during idle
time)
+11.0
FZP
BYTE
Error counter, active (errors during
communication)
+12.0
ANWZ
BYTE
Presence counter
+13.0
to
+16.0
res.
BYTE
Reserved
=18.0
END_STRUCT