background image

User Information

   

 

 

 

 

 

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]  

2-Hand Safety Relay, Series ESM-2H2.. 

V1.1.0 

• 

Up to PL e, SILCL 3, category 4 

Correct Use 

The  ESM-2H2..  2-hand  safety  relay  is  an  extremely 
compact,  universal  safety  two-hand  control  unit.  It 
complies with EN574, Typ III C, and is intended for use 
in safety  circuits that are designed in accordance with 
EN  60204-1,  e.g.  on  presses,  punches  and  bending 
tools.  Due  to  the  internal  error  monitoring,  the  2-hand 
safety relay can be used, despite very compact dimen-
sions, for all applications up to the highest safety cate-
gory 4 and  PL e according to EN ISO 13849-1, SILCL 3 
according to EN 62061 or Typ III C according to EN 574.
 

Features 

• 

2 safe, redundant relay outputs 

• 

Cyclical monitoring of the output contacts 

• 

Feedback loop for monitoring downstream contactors or 
expansion modules 

• 

Short circuit and earth fault monitoring 

• 

Extrem compact housing 

Function 

The EUCHNER  2-hand safety  relay  ESM-2H2..  is  suitable 
for setting up and monitoring two-hand circuits and is used 
to protect the operators. Dangerous work steps can only be 
triggered  when  both  two-hand  buttons  connected  are  ope-
rated simultaneously, i.e. within 0.5 s. 

It is to be  ensured  a single fault  or  a  malfunction does  not 
result  in  the  loss  of  the  safety  function  and  every  fault  is 
detected  by  the  cyclic  self-monitoring  at  the  latest  prior  to 
the next actuation. 

When  the  operating  voltage  is  applied  to  A1-A2  and  the 
feedback loop X1-X2 is closed, the ESM-2H2.. is ready for 
use. To be able to initiate a switching operation, the output 
relays must be de-energized. The output relays only switch 
to  the  energized  position  when  the  two-hand  buttons  T1 
and T2 are operated simultaneously, i.e. within 0.5s.  

Fig. 1 Block diagram ESM-2H2.. 

Installation 

As per DIN EN 60204-1, the device is intended for installa-
tion in control cabinets with a minimum degree of protection 
of IP54. It is mounted on a 35 mm DIN rail according to DIN 
EN 60715 TH35. 

Safety Precauti-
ons 

Fig. 2 Installation/removal 

Electrical Connec-
tion 

• 

When the 24 V version is used, a safety transformer 
according to EN 61558-2-6 or a power supply unit with 
electrical isolation from the mains must be connected. 

• 

External fusing of the safety contacts (6 A slow-blow or 8 
A quick-action or 10 A gG) must be provided. 

• 

A maximum length of the control lines of 1000 meters 
with a line cross section of 0.75 mm

2

 must not be excee-

ded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty. 

Fig. 3 Connections 

A1: 

Power supply 

A2. 

Power supply 

S11:  

Control line T1 

S12: 

Control line T1 

S13: 

Control line T1 

S21: 

Control line T2 

S22: 

Control line T2 

S23: 

Control line T2 

X1; X2: 

Feedback loop 

13-14:  

Safety contact 1 

23-24:  

Safety contact 2 

The output relays are not switched if: 

• 

only one two-hand button is actuated or the time between the actuation of the 2 two-hand buttons is greater than 0.5 s, 

• 

the feedback loop is open (fault in the external contactor), 

• 

another error (short circuit, cable break, error in the switching device) has occurred. 

When T1 and/or T2 are/is released, the output relays opens immediately. In order to trigger a new operation, both two-hand 

buttons must first be released and the feedback loop must be closed. 

 

• 

All relevant safety regulations and standards are to be 
observed. 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage. 

• 

Note down the version of the product (see label “Vx.x.x”) 
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of 
the control system in which the device is incorporated 
must be validated again by the user. 

• 

Installation and commissioning of the device must be 
performed only by authorized personnel

• 

Observe the country-specific regulations when installing 
the device. 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost. 

• 

It is not allowed to open the device, tamper with the 
device or bypass the safety devices. 

Summary of Contents for ESM-2H201

Page 1: ... When the 24 V version is used a safety transformer according to EN 61558 2 6 or a power supply unit with electrical isolation from the mains must be connected External fusing of the safety contacts 6 A slow blow or 8 A quick action or 10 A gG must be provided A maximum length of the control lines of 1000 meters with a line cross section of 0 75 mm2 must not be excee ded The line cross section mus...

Page 2: ...r bypassing of the safety device The arrangement of the two hand buttons must be designed in accordance with the standard EN 574 such that accidental actuation or simple bypassing of the safety function is excluded The operation of both buttons using one hand must be prevented by an adequate distance at least 260 mm or by a separa ting wall Actuation using forearm elbow knee hip or other parts of ...

Page 3: ...ing voltage AC 250 V Safety contact breaking capacity AC 250 V 2000 VA 6 A for ohmic load 250 V 3 A for AC 15 DC 24 V 192 W 6 A for ohmic load 24 V 3 A for DC 13 Max total current through all contacts 12 A Minimum contact load 24 V 20 mA Contact fuses 6 A slow blow or 8 A quick action or 10 A gG Line cross section 0 14 2 5 mm2 Max length of control line 1000 m with 0 75 mm2 Contact material AgSNO2...

Page 4: ...75 33 16 www euchner de info euchner de 2 Hand Safety Relay Series ESM 2H2 V1 1 0 Dimension Drawing Subject to technical modifications no responsibility is accepted for the accuracy of this information EUCHNER GmbH Co KG 109071 05 03 15 Translation of the Original Operating Instructions Fixed Terminals Plug In Terminals ...

Reviews: