Parameterizing
3.2 MOBY commands
FC 45
3-14
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
SLG status
Table 3-10 SLG status
Command
[hex]
sub_command
[hex]
length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Note
04
01 = status after
UDT 110
1
02 = status after
UDT 120
1
(last commands)
03 = status after
UDT 130
1
(error messages)
04 = status after
UDT 140
1
(MDS in field)
05 = status after
UDT 150
(communication quality)
06 = Status after
UDT 280
(diagnostics data)
–
–
Pointer to
result.
The result is
indicated with the
respective UDT
(see
sub_command).
MOBY U/D
MOBY U
MOBY U
MOBY U
MOBY U
RF300
1) You will find the UDT description in Section "UDTs of FC45".
NEXT
Table 3-11 NEXT
Command
[hex]
sub_command
[hex]
length
[dec]
address_MDS
[hex]
DAT_DB
[dec]
Note
06
–
–
–
–
NEXT: Processing of
this MDS is finished.
The NEXT command can also be used in a command chain (see Section "Command
chaining"). However, the NEXT command must always be the last command in the chain.