![Siemens SIJECT 16i Operation Manual Download Page 44](http://html.mh-extra.com/html/siemens/siject-16i/siject-16i_operation-manual_1265324044.webp)
SIJECT OP15B Screens
SIJECT 16i Operation Manual
3-18
3.1.5 Timer screen
Fig 3-19
Timer screen
Operating sequences
Press this key to enter the Timer screen. See Fig 3-19 Timer screen.
On this screen, the working time for every action and the delay time for
action switch, as well as protection time for charging can be set.
Cycle time (TmCyc)
It is the time to monitor one machine cycle. If the
actual machine cycle time is longer than the set value, then there is alarm.
Interval time (Interval)
When one cycle is finished, there is an interval
time before the next machine cycle start. This setting is only applicable in
time auto mode.
Cooling time (TcCool)
When injection is finished, the timer begins to
work. This interval is to make sure that the material has enough time for
cooling.
Charging delay (TdCha)
It is the interval time between injection and
charging, which is to prevent the overheating of plastic material.
Injection delay (TdInj)
When the carriage arrives at the injection
position, it will wait certain time before injection.
Core in delay (TdCorIn)
When previous work is finished, core in will
begin after a delay time.
Core out delay (TdCorOut)
When previous work is finished, core out
will begin after a delay time.
Ejector advance delay (TdEjeAdv)
When mold open is ended, ejector
advance will begin after a delay time.
Ejector retract delay (TdEjeRet)
When ejector advance is finished,
ejector retract will begin after a delay time.
Mold close time (TmMldClo)
The total time for mold close, which is
monitoring time. There is event message if the setting time is exceeded.
Mold open time (TmMldOpn)
The total time for mold open, which is
monitoring time. There is alarm if the setting time is exceeded.