Operator panel keys
SIJECT 16i Operation Manual
2-6
Load/Save key
Press this key to enter Load/Save screen. Mold recipe data can be saved
into CI/MMC, and saved mold recipe data can be loaded from CI/MMC.
Data key
Press this key to enter Data screen. You can review the production data of
last 10 injection cycles, including the position and time of each activity,
such as injection number, the position of mold open end point, injection
start point, injection end point, pressure hold end point, charging end point
and ejector end point, and the time for mold hold, mold lock, injection, cycle
and charging.
Service key
Press this key to enter Service screen. OEM can set the factory data and
functions here. Nine service screens are provided, including function
selection, linear scale setting, password setting, load/save setting,
proportional valve setting, pump setting, lubrication setting, temperature
setting and ramp setting.
When OEM has finished the start-up of injection molding machine, these
parameters will normally be protected by Password 2 by OEM.
Information key
Press Information key to enter Information screen where the version
message of OP, CI and PLC program can be read. Then press the softkey
F2, and continue to display the PLC status and OP communication status.
Users can also check the operating status of each digital input/output.
Monitoring key
Press Monitoring key to enter Monitoring screen, which is the main
screen of system. The current machine running statuses are displayed,
including the positions of mold, screw, ejector; rotation speed of screw;
production quantity; power on time; cycle time and current mold number.
Additionally, the purge and lubrication can also be operated.