Technical data
8.1 Technical specifications of the SCALANCE XR524-8C
SCALANCE XR-500
76
Operating Instructions, 05/2014, A5E03275845-05
Technical specifications
1 x 100 to 240 VAC
Design
IEC plug C14 with switch,
2-pin
Rated voltage
100 / 240 VAC
Voltage range
90 to 264 VAC
Frequency
60 Hz / 50 Hz
Frequency range
47 Hz to 63 Hz
Fusing
3.15 A / 250 V
Current consumption at 100 VAC
0.22 A
Current consumption at 240 VAC
0.17 A
Effective power loss
24 W
Properties
Not implemented redundantly
2 x 100 to 240 VAC
Design
IEC plug C14 with switch,
2-pin
Rated voltage
100 / 240 VAC
Voltage range
90 to 264 VAC
Frequency
60 Hz / 50 Hz
Frequency range
47 Hz to 63 Hz
Fusing
3.15 A / 250 V
Current consumption at 100 VAC
0.22 A
Current consumption at 240 VAC
0.17 A
Effective power loss
24 W
Properties
Implemented redundantly
Permitted ambient conditions
Ambient temperature
For devices with a 24 VDC
During operation up to 2000 m
-
40 ℃ to +70 ℃
During operation up to 3000 m
-
40 ℃ to +65 ℃
During storage
-
40 ℃ to +85 ℃
During transportation
-
40 ℃ to +85 ℃
Ambient temperature
for devices with 100 to 240 VAC
During operation up to 2000 m
-25 °C to +60 °C
During operation up to 3000 m
-25 °C to +55 °C
During storage
-40 °C to +85 °C
During transportation
-40 °C to +85 °C
Relative humidity
During operation at 25 ℃
≤ 95%, no condensation