Assembling
4.6 Plugging and pulling MM900 media modules
SCALANCE XR-500
Operating Instructions, 05/2014, A5E03275845-05
39
Pulling a media module
To pull a media module, follow the same steps as when plugging, but in the reverse order:
1.
Pull out the handle of the media module.
2.
Pull the media module out of the device slot.
3.
Close the device slot with a dummy cover if you are not plugging in another module.
NOTICE
Operating the device only with closed module slots
The device meets degree of protection IP20, if all the module slots have either media
modules inserted or are closed by dummy covers. Do not start up the device with open
module slots since the ingress of objects can lead to damage.
If you operate the device with open module compartments, it is also not possible to
guarantee the maximum ambient temperature.
Exchanging media modules - with change of medium
Exchanging a media module
If you replace an electrical media module with an optical media module (or vice versa), this
can lead to malfunctions. The IE switch therefore reacts as follows:
●
The media module is disabled.
●
The red fault LED "F" lights up.
●
The event is shown in the log table in WBM.
Enabling a media module
To enable the replacement media module, restart the IE switch:
●
The media module is active.
●
The red fault LED "F" goes off.