Technical specifications
Power supply
Rated voltage
24 V DC
Voltage range
19.2 to 28.8 V DC Safe Extra Low Voltage
(SELV)
Design
3-terminal plug-in block
Current consumption
Typical
190 mA
Power loss at 24 V DC
Typical
4.6 W
Overvoltage category
CAT II
Overvoltage protection at input
PTC resettable fuse (1.0 A / 60 V)
Permitted ambient conditions
Ambient temperature
During operation
-10 ℃ to +60 ℃
During storage
-40 ℃ to +85 ℃
During transportation
-40 ℃ to +85 ℃
Relative humidity
During operation
≤ 95 % no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. +60 °C
ambient temperature
< 3,000 m above sea level at max. +55 °C
ambient temperature
< 4,000 m above sea level at max. +50 °C
ambient temperature
Design, dimensions and weight
Immunity
EN 61000-6-2
Emission
EN 61000-6-4
Degree of protection
IP20
MTBF (EN/IEC 61709; 40 °C)
217 years
Housing material
Polycarbonate (plastic)
Weight
188 g
Dimensions (W x H x D)
45 x 100 x 87 mm
Installation options
• Mounting on a DIN rail
• Wall mounting
Switching properties
Aging time
45 seconds
Max. number of learnable MAC ad‐
dresses
16000
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
8
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Yes
Maximum frame size
1536 bytes
Forwarding of PRP frames (Parallel Re‐
dundancy Protocol)
Yes
Technical specifications
8.10 SCALANCE XB008G
SCALANCE XB-000
Operating Instructions, 01/2022, A2B00077300-11
87