System Messages
C-11
MP270 Equipment Manual
Release 01/99
Remedy
Effect/Cause
Number
220001
The tag is not downloaded because the associated
channel/the unit does not support downloading the
data type bool/bit.
Change the configuration.
220002
The tag is not downloaded because the associated
channel/the unit does not support downloading the
data type byte.
Change the configuration.
220003
The associated driver could not be uploaded. It is
possible that the driver is not installed.
Install the driver by re-installing
ProTool/Pro RT.
220004
Communication is terminated and no update is
executed because the cable is not connected or is
defect etc.
Check the connection.
220005
Communication is running.
–
230000
The value entered could not be accepted. The
entered value is rejected and the previous value is
specified again.
Either the value range has been exceeded or
impermissible characters were entered.
Enter a permissible value.
230002
Since the current password level is inadequate or the
password dialog box was closed with ESC, the entry
is rejected and the previous value is specified again.
Activate an adequate password
level using Login.
230003
Changeover to the specified screen is not executed
because the screen is not available/configured. The
current screen remains selected.
Configure the screen.
Check the selection function.
240000
3)
Runtime is operating in Demo mode.
There is either no Stopcopy license or it is defect.
Load the license.
240001
3)
Runtime is operating in Demo mode.
Too many tags are configured for the installed version.
Load an adequate license /
powerpack.
240002
3)
Runtime is operating with a time-limited standby
authorization.
Restore the full authorization.
240003
Authorization cannot be executed.
ProTool/Pro RT is running in Demo
mode.
Restart ProTool/Pro RT or reinstall
it.
240004
Error during reading the the standby authorization.
ProTool/Pro RT is running in Demo mode.
Restart Sie ProTool/Pro RT, install
the authorization or repair the
authorization (see Commissioning
Instructions Software Protection).
250000
The tag in the specified line in Status/Control is not
updated because the address configured for this tag
is not available.
Check the set address and then
check that the address has been
set up in the PLC.
250001
The tag in the specified line in Status/Control is not
updated because the PLC type configured for this tag
is not available.
Check the set address.
250002
The tag in the specified line in Status/Control is not
updated because it is not possible to map the PLC
type in the tag type.
Check the set address.
260001
A password has been entered which is unknown to
the system. Therefore, the lowest password level has
been set. This corresponds to the status following
Logout.
Enter a known password in the
password input field (with
corresponding level).
Summary of Contents for Multi Panel MP270 SIMATIC HMI
Page 8: ...Preface vi MP270Equipment Manual Release01 99 ...
Page 18: ...Functionality 2 4 MP270EquipmentManual Release01 99 ...
Page 36: ...MP270 Operation 4 14 MP270Equipment Manual Release01 99 ...
Page 64: ...System Settings 6 8 MP270Equipment Manual Release01 99 ...
Page 82: ...Unit Description 8 8 MP270Equipment Manual Release01 99 ...
Page 90: ...Maintenance Upkeep 10 4 MP270Equipment Manual Release01 99 ...
Page 92: ...APPENDICES J 2 MP270Equipment Manual Release01 99 ...
Page 98: ...Technical Data A 6 MP270Equipment Manual Release01 99 ...
Page 114: ...System Messages C 14 MP270Equipment Manual Release01 99 ...
Page 144: ...Index Index 8 MP270Equipment Manual Release01 99 ...