R 01.04
E-65
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
Error Designation Possible Causes and Their Correction
111
Timeout during initialization (MOBY I)
S
The MDS is located in the boundary area of the read head.
S
An MDS 507 is initialized but MDS 507 mode has not been
enabled under “Extras/MOBY I Setup.”
The MDS memory cannot be read correctly (MOBY U).
112
S
The MDS memory cannot be written and is defective.
S
The OTP memory cannot be written again.
113
The address area of the MDS was exceeded.
S
Check the memory size under “Extras/MOBY I Setup” or
“Extras/MOBY U Setup.”
114
ECC error or MDS not initialized in ECC mode
S
Enable ECC mode under “Extras/MOBY I Setup,” and then
execute the INIT command.
115
Reset message after return of power
S
The hand-held terminal has a defect in the power supply to
the read head. (Try charging/replacing the batteries.)
S
The hardware of the read head has a defect.
125
Internal program error. Previous command is active.
129
The number of MDSs in the field is not permitted. Number of
MDS > multitag in the “SLG Status” function under “Extras.”
130
Internal program error. The telegram layout of the command to
the read head is wrong.
180 to 243
Internal program error (MDS D1xx)
Turn the device off and on again. If error continues to occur,
contact Customer Support and specify the error number.
251
Read/write comparison not successful
255
No card/no MDS in the field
Error Messages
Summary of Contents for MOBY D
Page 6: ...R 01 04 E IV STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 Table of Contents ...
Page 86: ...R 01 04 E 80 STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Table Appendix ...
Page 94: ...A 01 04 D IV Handterminal STG 5 J31069 D0126 U001 A5 1 7418 Inhaltsverzeichnis ...
Page 174: ...A 01 04 D 80 Handterminal STG 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Tabelle Anhang Anhang ...