R 01.04
E-55
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
The length of the READ or WRITE file is the same as that of the MDS which
was read.
READ_D.HEX:
44 bytes for I-Code1
112 bytes for I-Code SLI
256 bytes for Tag-it HF-I
1000 bytes for my-d
READ_E.HEX: 768 bytes for MOBY E (in normal mode)
1024 bytes for MOBY E (after reading the raw data)
1024 bytes for MOBY E (in SIM mode)
READ_F.HEX:
5 bytes for MOBY F (after reading an F1xx MDS)
192 bytes for MOBY F (after reading an F4xx MDS)
256 bytes for MOBY F (after reading the raw data of an
F4xx MDS)
READ_I.HEX:
Setup Setting
No ECC
With ECC
62 bytes
128 bytes
2 KB
8 KB
32 KB
62
128
2045
8189
32765
42
112
1778
7154
28658
READ_U.HEX:
Setup Setting
2 KB
32 KB
2048
32768
The contents of the file can now be indicated and changed with an appropriate
editor on your PC.
When ASCII data were read from the MDS:
Any editor can be used (e.g., NOTEPAD, WRITE, WORD and so on).
When binary data were exchanged with the MDS:
Use a HEX editor. HEX editors are available on the shareware market
(e.g., Hedit and so on) or on the professional market (e.g., Codewright).
After concluding your session with PsiWin, the remote-link connection should
be disconnected again.
To restart the STG application, see chapter 6.7.
Before starting a new session with PsiWin, the STG application should be ex-
ited.
Expanded Functions
Summary of Contents for MOBY D
Page 6: ...R 01 04 E IV STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 Table of Contents ...
Page 86: ...R 01 04 E 80 STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Table Appendix ...
Page 94: ...A 01 04 D IV Handterminal STG 5 J31069 D0126 U001 A5 1 7418 Inhaltsverzeichnis ...
Page 174: ...A 01 04 D 80 Handterminal STG 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Tabelle Anhang Anhang ...