R 01.04
E-34
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.1-7418
4.5.7
MOBY U Setup
S
Memory size:
Specify memory size of the MDS to be processed. This
setting can also be used to specify the memory area in
the editor. MDS memory addresses beyond the memory
size cannot be accessed.
S
Standby time:
The standby time can be set in increments of 7 msec
from 0 msec to 1400 msec. The default value (OFF)
usually does not have to be changed.
S
Working range
The field length (limit distance) is 3 m. It can be set in
limitation:
increments of 0.5 m to avoid excess working ranges for
the antenna.
The setting range is between 0.5 m and 3.5 m. The
default value is 1 m.
4.5.8
SLG Status
Only MOBY U: The SLG Status function can be used to read version states and
settings of the MOBY U antenna.
The information can be accessed with the “Enter” key in 3 consecutive screens.
S
Screen 1:
Hardware, firmware and loader version
S
Screen 2:
Driver model, driver version and interface parameters
S
Screen 3:
Set working range limitation, standby time and multitagging
(equals 1)
The “MOBY D/E/F/I/U” Programs
Summary of Contents for MOBY D
Page 6: ...R 01 04 E IV STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 Table of Contents ...
Page 86: ...R 01 04 E 80 STG Hand Held Terminal 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Table Appendix ...
Page 94: ...A 01 04 D IV Handterminal STG 5 J31069 D0126 U001 A5 1 7418 Inhaltsverzeichnis ...
Page 174: ...A 01 04 D 80 Handterminal STG 5 J31069 D0126 U001 A5 1 7418 A 3 ASCII Tabelle Anhang Anhang ...