Reading Raw Data
Only MOBY D/E/F: This function is used to physically read the entire memory of
the MDS. This includes TagId, key information (if public), manufacturer’s
information and MDS access rights. A knowledge of the physical layout of the
MDS memory is required to interpret the data. See description of MFWAPI or
CCTWAPI.
The “read raw data” function can be used to detect errors made when the MDS
was configured.
Note
For MOBY F
MDS addresses 8 to 3F hex (i.e., pages 2 to 15) cannot be read.
They are always shown by the editor as 00.
The “MOBY D/E/F/I/U” Programs