9 Electro-Magnetic Compatibility (EMC)
International English
MICROMASTER 440 Operating instructions
94
6SE6400-5CA00-0BP0
9.1.5
Three General classes of EMC performance are available as
detailed below
Class 1: General Industrial
Compliance with the EMC Product Standard for Power Drive Systems EN 68100-3
for use in
Second Environment (Industrial)
and
Restricted Distribution
.
Table 9-1
Class 1 - General Industrial
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level A1
Conducted Emissions
EN 68100-3
Limits under consideration
Immunity:
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables, 1 kV control
Radio Frequency Electromagnetic Field IEC 1000-4-3
26-1000 MHz, 10 V/m
Class 2: Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 50082-2.
Table 9-2
Class 2 - Filtered Industrial
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level A1
Conducted Emissions
EN 55011
Level A1
Immunity:
Supply Voltage Distortion
IEC 1000-2-4
(1993)
Voltage Fluctuations, Dips, Unbalance,
Frequency Variations
IEC 1000-2-1
Magnetic Fields
EN 61000-4-8
50 Hz, 30 A/m
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables, 2 kV control
Radio Frequency Electromagnetic
Field, amplitude modulated
ENV 50 140
80-1000 MHz, 10 V/m, 80% AM, power
and signal lines
Radio-frequency Electromagnetic Field,
pulse modulated
ENV 50 204
900 MHz, 10 V/m 50% duty cycle, 200 Hz
repetition rate